OPERATING INSTRUCTIONS - MILLIVOLT
and
REMOTE HI/LO
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
• Soap and water solution
• An approved leak testing spray
• Electronic sniffer
NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.
1. Depress and turn knob counterclockwise
to pilot position.
2. Depress fully and hold pilot gas knob. Depress piezo
ignitor as many times as needed to ignite the pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
Figure 58 - Pilot Position
Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
• Burner connections
• Field made joints / gas shutoff valve
• Pilot
• Factory made joints
• Each joint or connection
• All joints on valve and control body
LIGHTING PILOT FOR THE FIRST TIME
MILLIVOLT
and
REMOTE HI/LO
W
ARNING
If using a soap and water
solution to test for leaks,
DO NOT spray solution
onto control body.
DANGER
Never check for gas leak with open flame!
LIGHTING PILOT - MILLIVOLT
and
REMOTE HI/LO
For lighting burner on Millivolt units, see page 42.
For lighting burner on Remote HI/LO units, see page 44.
Содержание 500DVH Series
Страница 56: ...56 56D3049 1 5 10 3 2 4 6 9 8 13 7 12 11 11 illustrated parts lists firebox components...
Страница 58: ...58 56D3049 illustrated parts lists additional Accessories 1 2 3 4 5...
Страница 62: ...62 56D3049 1 2 3 4 5 6 7 L O HI illustrated parts lists 1 2 3A 3B 3C 4 5 6 9 ELECTRONIC IGNITION 8 10 11 7B 7A...
Страница 72: ...72 56D3049 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com AUGUST 2008 56D3049 Rev 3...