background image

62D4037

33

ILLUSTRATED PARTS LIST

STANDING PILOT - MILLIVOLT CONTROL

 

Item  Description 

Qty. 

400BBVNV 

400BBVPV 

400SBVNV  400SBVPV 

500SBVNV  500SBVPV

 

1. 

Gas Valve Assembly 

37D0117 

37D0118 

37D0117 

37D0118 

37D0117 

37D0118

 

2. 

Pilot Assembly 

37D0018 

37D0019 

37D0018 

37D0019 

37D0018 

37D0019

  2C.  Replacement  

 

 

 

 

 

 

 

 

 

 

Thermocouple 

37D1067 

37D1067 

37D1067 

37D1067 

37D1067 

37D1067

 

2I. 

Replacement Igniter 

 

 

 

 

 

 

 

 

 

 

and Wire 

37D1069 

37D1069 

37D1069 

37D1069 

37D1069 

37D1069

  2T.  Replacement Thermopile  1 

37D1068 

37D1068 

37D1068 

37D1068 

37D1068 

37D1068

 

3. 

Burner Tube 

62D4051 

62D4051 

62D4052 

62D4052 

62D4053 

62D4053

 

4. 

Flexhose with 

 

 

 

 

 

 

 

 

 

 

Shut-off Valve 

23D6046 

23D6046 

23D6046 

23D6046 

23D6046 

23D6046

 

5. 

Rocker Switch 

41D0048 

41D0048 

41D0048 

41D0048 

41D0048 

41D0048

 

6. 

Piezo Igniter 

14D0503 

14D0503 

14D0503 

14D0503 

14D0503 

14D0503

 

7. 

Injector 

62D3006 

62D3005 

62D3004 

20H3143 

62D3003 

59D0094

 

8. 

Burner Assembly 

54D0200 

54D0200 

54D0001 

54D0001 

54D0329 

54D0329

 

9. 

Venturi 

45D0600 

45D0600 

45D0600 

45D0600 

45D0600 

45D0600

  10.  Wire Assembly 

44D0500 

44D0500 

44D0500 

44D0500 

44D0500 

44D0500

  10.  Wire Assembly 

44D0501 

44D0501 

44D0501 

44D0501 

44D0501 

44D0501

  11.  Spill Switch 

62D0048 

62D0048 

073746 

073746 

073746 

073746

 Accessories

  12.  Remote Control On/Off 

RCM/RCB 

RCM/RCB 

RCM/RCB 

RCM/RC 

RCM/RCB 

RCM/RCB

  13.  wall Switch Kit 

MVWTS 

MVWTS 

MVWTS 

MVWTS 

MVWTS 

MVWTS

 Conversion Kit

 (not shown)

 

 

400BBV Conversion 

 

 

 

 

 

 

 

 

 

 

NG to LP 

400BBVCKP 

-- 

-- 

-- 

-- 

--

 

 

400BBV Conversion 

 

 

 

 

 

 

 

 

 

 

LP to NG 

-- 

400BBVCKN 

-- 

-- 

-- 

--

 

 

400SBV Conversion 

 

 

 

 

 

 

 

 

 

 

NG to LP 

-- 

-- 

400SBVCKP 

-- 

-- 

--

 

 

400SBV Conversion 

 

 

 

 

 

 

 

 

 

 

LP to NG 

-- 

-- 

-- 

400SBVCKN 

-- 

--

 

 

500SBV Conversion 

 

 

 

 

 

 

 

 

 

 

NG to LP 

-- 

-- 

-- 

-- 

500SBVCKP 

--

 

 

500SBV Conversion 

 

 

 

 

 

 

 

 

 

 

LP to NG 

-- 

-- 

-- 

-- 

-- 

500SBVCKN

Содержание 400BBV

Страница 1: ...taller service agency or the gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this man ual For assistance or additi...

Страница 2: ...ecautions 14 Installation Planning 14 Outside Combustion Air Precautions and Rec ommendations 16 Combustion Air Assembly 17 Fireplace Installation 18 Check Gas Type 18 Installing Gas Piping to Firepla...

Страница 3: ...rformance problems do not use propane LP fuel tank of less than 100 lbs capacity 3 If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical switch do not use...

Страница 4: ...not intended for use with a thermo stat 22 This appliance must be installed with draft hood in same atmospheric pressure zone as the combustion air inlet to the appliance 23 For Massachusetts Resident...

Страница 5: ...ion code ANSI Z223 1 NFPA 54 in the US and CSA B149 in Canada The appliance must be properly connected to a venting system The appliance is not approved for closet or recessed installations Gas Contro...

Страница 6: ...0 Min BTU hr Input 16 000 14 500 16 500 16 300 19 000 20 000 Burner Ori ce size as shipped 43 55 41 53 37 52 BEFORE YOU START Read this homeowner manual thoroughly and follow all instructions carefull...

Страница 7: ...priate height When the rebox is installed directly on carpeting tile or other combustible material other than wood ooring the rebox shall be installed on a metal or wood panel extending the full width...

Страница 8: ...raming Dimension 14 1 2 or 5 8 Drywall Spacers 1 2 or 5 8 Drywall Spacers 8 9 Air Kit 16 7 Electrical Gas Access 2 40 40 Framing Dimension 21 34 6 B C D Framing Dimension 624037 400 BBV dims 10 08 4 B...

Страница 9: ...f the gas knock out hole lo cated at the bottom of the left side NOTE 400SBV 500SBV A 24 30 B 36 42 C 40 46 D 40 46 A 21 Framing Dimension 21 13 6 1 2 or 5 8 Drywall Spacers 1 2 or 5 8 Drywall Spacers...

Страница 10: ...k and windows Minimum clearances to combustibles must be maintained This replace may be installed along a wall across a corner or use an exterior chase Location should be out of high traf c areas and...

Страница 11: ...not be installed on a carpet tile or other combustible material other than wood ooring If installed on carpet or vinyl ooring the appliance shall be installed on a metal wood or noncombustible materia...

Страница 12: ...screws to secure replace to the oor Use four 4 screws to attach replace to framing The side brackets are adjustable from 1 2 to 5 8 to accommodate different thicknesses of material Framing 1 2 Nail F...

Страница 13: ...his may create a re hazard Only noncombustible materials i e brick tile slate steel or other materials with a UL re rating of Zero may be used to cover the black surface of the appliance A 300 F minim...

Страница 14: ...us injury property damage or loss of life Operation of improperly installed and maintained venting system could result in serious injury property damage or loss of life NOTICE Failure to follow these...

Страница 15: ...stop in Ceiling When installing in a chase you should insulate the chase as you would the out side walls of your home This is especially important in cold climates Insulation should be considered a co...

Страница 16: ...sure the location cannot be accidentally blocked Locate assembly above snow line to prevent snow from blocking assembly 3 Never mount combustion air inlet assem bly in garage or storage area where co...

Страница 17: ...th a standard pocket knife Figure 14 WARNING DO NOT remove the cover if the outside air will not be connected WARNING Do not use a combustible duct Always use UL Listed Class 0 or 1 duct material If n...

Страница 18: ...m regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 16 Pointing the vent down protects it from freezing rain or sleet WARNING A quali ed installer...

Страница 19: ...the replace Check your building codes for any special requirements for locating equipment shut off valve to replaces Apply pipe joint sealant lightly to male threads This will pre vent excess sealant...

Страница 20: ...gas meter to the replace for leaks Use a solution of 50 50 water and soap or a gas sniffer 4 To adjust ame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob to LO to get...

Страница 21: ...d only be performed by a quali ed licensed electrician Main power must be off when connecting to main electrical power supply or performing service All wiring shall be in compliance with all local cit...

Страница 22: ...ion the wall switch Do not extend beyond the 15 of wire OPTIONAL DC REMOTE SYSTEMS These instructions replace the section entitled Hearth Mount in the Millivolt hand held remote in structions supplied...

Страница 23: ...rear log 1 on grate assembly Log should rest rmly on the two log mounting pins on the hori zontal bars Figure 22 2 Place bottom left log 2 on grate Rest the back side of the log in the at area of the...

Страница 24: ...Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it Call a quali ed service technician Force or attempted re...

Страница 25: ...using a soap and water solu tion to test for leaks DO NOT spray solution onto control body DANGER Never check for gas leaks with open ame NOTE Remove any excessive pipe compound from the connec tions...

Страница 26: ...he ON posi tion to light the main burner Figure 24 LIGHTING THE BURNER Depress and turn the knob counterclockwise to the ON position Fig ure 25 It will take less than four 4 seconds for the burner to...

Страница 27: ...of it has been under water Immediately call a quali ed service technician to inspect the appliance and to replace any pat of the control system and any gas control that has been under water LIGHTING E...

Страница 28: ...e pilot ame must always be present when the replace is in operation Figure 29 The pilot ame has three distinct ames one engul ng the thermopile one engul ng the thermo couple and the other reaching to...

Страница 29: ...with a brush attachment If logs must be removed for cleaning handle carefully by holding gently at each end Gloves are recom mended to prevent skin irritation from ceramic bers If skin becomes irrita...

Страница 30: ...62D4037 30 ILLUSTRATED PARTS LIST FIREBOX COMPONENTS 4a 4b 4c 1 2 3 5 6 7...

Страница 31: ...ctory 1 n a 62D1017 62D2017 Optional Field Installed Accessoriesd 5 Firebrick Assembly 1 F400BBVW n a n a 6 Outside Air Kit 1 OAC4 OAC4 OAC4 7 Black Glass Door Assembly 1 GD36BA GD36BA GD36BA 7 Polish...

Страница 32: ...62D4037 32 ILLUSTRATED PARTS LIST STANDING PILOT MILLIVOLT CONTROL 1 2 3 4 5 6 7 8 10 12 13 2T 2I 2C 9 11...

Страница 33: ...0048 41D0048 41D0048 41D0048 41D0048 6 Piezo Igniter 1 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 7 Injector 1 62D3006 62D3005 62D3004 20H3143 62D3003 59D0094 8 Burner Assembly 1 54D0200 54D0200...

Страница 34: ...62D4037 34 ILLUSTRATED PARTS LIST ELECTRONIC IGNITION 1 2 3 4 5 6 7 9 8 10 11 12...

Страница 35: ...23D6046 23D6046 23D6046 23D6046 23D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 6 Injector 1 62D3006 62D3005 62D3004 20H3143 62D3003 62D0094 7 Burner Assembly 1 54D02...

Страница 36: ...the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one mil livolt lead wire on the tip of the thermocouple and the other meter lead wire on the thermocouple co...

Страница 37: ...heck electrical connections between module and pilot operator on gas control C Check for 24VAC across PV MVPV terminals If voltage is correct replace gas control If voltage is not correct replace modu...

Страница 38: ...age or restriction in venting ACTION A Install log set per instructions Inspect the injector and air intake area Make sure this area does not have any blockage from debris and clean Check gas supply A...

Страница 39: ...he follwing requirements shall be satis ed 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of installation of the side wall horizontal vented gas fueled equipment the installing plumber or gas...

Страница 40: ...ions provided by the manufacturer for installation of the equipment and the venting system shall include 1 Detailed instructions for the installation of the venting system design or the venting system...

Страница 41: ...62D4037 41 NOTES...

Страница 42: ...62D4037 42 NOTES...

Страница 43: ...Warranty will also be void if the appliance is not operated and main tained according to the operating instructions supplied with the appliance and does not extend to 1 rebox burner assembly damage by...

Страница 44: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com OCTOBER 2008 62D4037 Rev 10...