62D4037
17
COMBUSTION AIR ASSEMBLY
MODEL OAC-4 COMBUSTION AIR ASSEM-
BLY
1. Remove the cover plate from the 4” outlet opening
location on the left outside of the fireplace.
2. Place starting collar (4”) into hole on left side of
fireplace. Fireplace shortest side of air starting collar
through fireplace outer wrap. Fasten starting collar
in place with four (4) sheet metal screws provided.
Figure 13
NOTE: The air starting collar extends through the
fireplace outer wrap. When the air starting collar is
securely attached, it will form a seal against the fire-
place wall.
3. Cut a 6” diameter opening for model OAC-4 in the
outside wall covering where the outside vent is to be
located.
Figure 15
4. Select and cut a piece of duct long enough to attach
to the fireplace and stick out at least 3” beyond the
face of the wall to which the OAC-4 inlet air vent will
be attached. Cut duct with a standard pocket knife.
Figure 14
W
ARNING
DO NOT remove the cover
if the outside air will not be
connected.
W
ARNING
Do not use a combustible duct. Always
use UL Listed Class 0 or 1 duct material.
If necessary to splice duct, use Model
403 duct connector to splice duct sec-
tions.
������
�������������������
�����
Left Side of
Fireplace
OAC-4
Starting
Collar
Sheet Metal
Screws
Shorter End of Air
Starting Collar
FP2023
Figure 13 -
Attach Outside Air Starting Collar to
Left Side of Fireplace
������
�����������������������
�����
Air Starting Collar
Screws
Screws
Duct
Left Side of
Fireplace
FP2024
Figure 14 - Attach Outside duct to Starting Collar
������
�������������
�����
6” Diameter
Hole
Duct Ex-
tending 3”
Min.
AK-4 Inlet Air
Vent
Nail
Hole
Screws
FP2025
Figure 15 -
Combustion Air Assembly for Model No. OAC-4
5. If using insulating duct, push the insulation back
from one end of the duct approximately 2”.
Figure 15
6. Slip the exposed end of the duct over the starting
collar on the fireplace.
7. Using the sheet metal screws provided, secure the
duct end to the collar attached to the fireplace.
8. Nail or screw the combustion air assembly to the
surface of the wall.
Содержание 400BBV
Страница 30: ...62D4037 30 ILLUSTRATED PARTS LIST FIREBOX COMPONENTS 4a 4b 4c 1 2 3 5 6 7...
Страница 32: ...62D4037 32 ILLUSTRATED PARTS LIST STANDING PILOT MILLIVOLT CONTROL 1 2 3 4 5 6 7 8 10 12 13 2T 2I 2C 9 11...
Страница 34: ...62D4037 34 ILLUSTRATED PARTS LIST ELECTRONIC IGNITION 1 2 3 4 5 6 7 9 8 10 11 12...
Страница 41: ...62D4037 41 NOTES...
Страница 42: ...62D4037 42 NOTES...
Страница 44: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com OCTOBER 2008 62D4037 Rev 10...