9.   The installation must conform with local codes or, in 

the absence of local codes, with the 

National Fuel Gas 

Code, ANSI Z223.l/NFPA54.

10.  This unit complies with ANSI Z21.91 ventless firebox 

enclosures for gas-fired unvented decorative room heat

-

ers.

11.  Do not install heater in a bathroom or bedroom.
12.  Correct installation of the logs, proper location of the 

heater,  and  annual  cleaning  are  necessary  to  avoid 

potential problems with sooting. Sooting, resulting from 

improper installation or operation, can settle on surfaces 

outside the fireplace. See log placement instructions for 

proper installation.

13.  Avoid any drafts that alter burner flame patterns. Do not 

allow fans to blow directly into fireplace. Do not place 

a blower inside burn area of firebox. Ceiling fans may 

create drafts that alter burner flame patterns. Sooting and 

improper burning will occur.

14. 

Caution:

  Candles,  incense,  oil  lamps,  etc.  produce 

combustion byproducts including soot. Vent-free appli-

ances will not filter or clean soot produced by these types 

of products. In addition, the smoke and/or aromatics 

(scents) may be reburnt in the vent-free appliance which 

can produce odors. It is recommended to minimize the 

use of candles, incense, etc. while the vent-free appliance 

is in operation. 

15.  An unvented gas-fired heater uses air (oxygen) from the 

room in which it is installed. Provisions for adequate 

combustion and ventilation air must be provided. See 

installation guidelines. 

OWNER

Please retain these instructions for future reference.

IMPORTANT

Read these instructions carefully before installing or trying to operate a vent-free gas heater in this firebox. 

IMPORTANT SAFETY INFORMATION

  1.  Due to high temperatures, the appliance should be 

located out of traffic and away from furniture and 

draperies.

  2.  Children and adults should be alerted to the hazard 

of high surface temperature and should stay away 

to avoid burns or clothing ignition.

  3.  Young  children  should  be  carefully  supervised 

when they are in the same room with the appli-

ance. 

  4.  Do not place clothing or other flammable material 

on or near the appliance. 

  5.  Any safety screen or guard removed for servicing 

an appliance, must be replaced prior to operating 

the heater.

  6.  Installation and repair should be done by a qualified 

service person.

  7.  To prevent malfunction and/or sooting, an unvented 

gas heater should be cleaned before use at least 

annually by a professional service person. More 

frequent cleaning may be required due to exces

-

sive lint from carpeting, bedding material, etc. It is 

imperative that control compartments, burners and 

circulating air passageways be kept clean.

8.

  

CARBON MONOXIDE POISONING:

 Early signs of 

carbon monoxide poisoning are similar to the flu with 

headaches, dizziness and/or nausea. If you have these 

signs,  obtain  fresh  air  immediately.  Have  the  heater 

serviced as it may not be operating properly.

Continued on page 4

• Any change to this heater or its controls can be dangerous.
• Improper installation or use of the heater can cause serious injury or death from fire, 

burns, explosion or carbon monoxide poisoning.

• Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner 

flame patterns.

• Do not use a blower insert, heat exchanger insert or other accessory, not approved for 

use with this heater where applicable.

W

ARNING

INSTALLER

Please leave these instructions with the appliance.

Содержание 32LCUF-F

Страница 1: ...TED VENT FREE FIREBOXES INSTALLATION AND OPERATING INSTRUCTIONS MODELS 32LCUF F 32LCUF R 36LCUFC R Carefully review the instructions supplied with the decorative type unvented room heater for the mini...

Страница 2: ...n Information 6 Firebox External Dimensions 6 Minimum Hearth Dimensions 7 Location of Firebox 7 Clearances and Height Requirements 8 Firebox Framing 10 Gas Line Installation 12 Canopy Installation 13...

Страница 3: ...operate a vent free gas heater in this firebox IMPORTANT SAFETY INFORMATION 1 Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies 2 Children...

Страница 4: ...nued use 20 Input ratings are shown in BTU per hour and are for elevations up to 2 000 feet For elevations above 2 000 feet input ratings should be reduced 4 percent for each 1 000 feet above sea leve...

Страница 5: ...ing Instructions 2 Canopy 4 Five 5 sheet metal screws for canopy What you will need for installation TOOLS BUILDING SUPPLIES Phillips screwdriver Square Framing materials Hammer Piping complying with...

Страница 6: ...ing or into prepared framing 2 Plumb gas line Gas connections should only be performed by an experienced licensed certified tradesman 3 Install vent free gas log heater per the instructions provided w...

Страница 7: ...indows or doors Installation must provide adequate ventilation and combustion air DO NOT INSTALL THIS FIREBOX IN A BED ROOM OR BATHROOM Location should be out of high traffic or windy or drafty areas...

Страница 8: ...back wall Figure 4 Clearance and Height Requirements 4 Floor clearance This inner chamber firebox floor must be installed at least 1 above any combustible flooring mate rial such as carpeting or aspha...

Страница 9: ...nit must be installed If a combustible mantel is installed it must meet the clearance requirements as shown in Figure 7A However if lower mantel height is desired see page 14 and Figure 7B for canopy...

Страница 10: ...pth of the enclosure The classification noncombustible material includes but is not limited to stone brick and mortar Noncombustibles are safe to overlay the black painted metal face including radiant...

Страница 11: ...mmodate the fireplace with trim installed is as follows Figure 13 Custom Cabinet Figure 14 Location of Nailing Flanges The fireplace must be installed giving full consideration to the clearance and he...

Страница 12: ...ters in addition to the regulator fitted to the heater to reduce the supply tank pressure to 13 w c maximum Any copper tubing used to supply propane L P G from the tank must be internally tinned Note...

Страница 13: ...he side frames See Figure 15 2 Align the canopy with the holes in the top frame 3 Replace the screws previously removed 4 Tighten side screws Make sure the canopy is level and secure The firebox canop...

Страница 14: ...F 32LCUF R 36LCUFC R 1 Canopy 1 71D0023 71D0023 71D0500 Screen Panel 2 070942 070942 26D4563 3 Screen Rod 2 26D0138 26D0138 26D0132K ACCESSORIES in KITS 1 Standard Brass Canopy 1 BRCU32 BRCU32 BRCU36...

Страница 15: ...or garage space 5 Locate air supply inlet at least 3 away from any applaince vent terminal 6 Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air...

Страница 16: ...lamp or screws See Figure 21 DO NOT remove the cover if the outside air will not be connected WARNING Figure 20 Attaching Outside Air Starting Collar and Insulation Ring to Left Side of Fireplace Figu...

Страница 17: ...l Note If the wall covering is brick or stone use appropriate masonry fasteners If necessary splice the duct Use a model 403 duct connector to splice duct sections Installing model 403 duct connector...

Страница 18: ...18 26D4751 notes...

Страница 19: ...d Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assemb...

Страница 20: ...AUGUST 2008 26D4751 Rev 10 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: