26D4751

GAS LINE INSTALLATION 

Consult all local codes. All gas piping must be installed to comply with local codes, or in the absence of local codes, with 

the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA54.
The 

1

/

2

" gas line may enter either from the left side or right side of the firebox. Gas access holes are provided on both sides 

of the firebox.

A listed manual shutoff valve must be installed upstream of the appliance. A union tee and plugged 

1

/

8

" NPT pressure tapping 

point should be installed upstream of hte appliance.

IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning 

on or shutting off the gas to the fireplace.

A sediment trap may be upstream of the heater to prevent moisture and contaminants from passing through trap to the heater 

controls and burners. Failure to do so could prevent the heater from operating reliably. Consult applicable codes.

An external regulator must be used on all propane/L.P.G. heaters, in addition to the regulator fitted to the heater, to reduce 

the supply tank pressure to 13" w.c. (maximum). Any copper tubing used to supply propane / L.P.G. from the tank must be 

internally tinned. 

Note: When connecting propane / L.P.G. vent-free room heaters, you must use pipe sealant resistant to 

propane / L.P.G.
Important: Hold heater regulator with a wrench to prevent movement when connecting to inlet piping.

Check gas type: the gas supply must be the same as stated on the heater’s rating plate. If the gas supply 

is different, DO NOT INSTALL THE HEATER. Contact your dealer for the correct model.

After completing connection, test all gas joints from the gas meter to the gas heater regulator for leaks. Using soap and water 

solution or a gas sniffer. DO NOT USE AN OPEN FLAME.

plumbing connections should only be performed by a qualified, licensed plumber. Main 

gas supply must be off when plumbing gas line to fireplace or performing service.

W

ARNING

Connecting directly to an unregulated 

propane  /  L.p.G.  tank  can  cause  an 

explosion.

W

ARNING

Do not connect directly to natural gas 1/2 PSI or 2 PSI systems. Always make sure 

natural gas pressure is regulated 10.5 w.c. (maximum before operating the unit). 

W

ARNING

Содержание 32LCUF-F

Страница 1: ...TED VENT FREE FIREBOXES INSTALLATION AND OPERATING INSTRUCTIONS MODELS 32LCUF F 32LCUF R 36LCUFC R Carefully review the instructions supplied with the decorative type unvented room heater for the mini...

Страница 2: ...n Information 6 Firebox External Dimensions 6 Minimum Hearth Dimensions 7 Location of Firebox 7 Clearances and Height Requirements 8 Firebox Framing 10 Gas Line Installation 12 Canopy Installation 13...

Страница 3: ...operate a vent free gas heater in this firebox IMPORTANT SAFETY INFORMATION 1 Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies 2 Children...

Страница 4: ...nued use 20 Input ratings are shown in BTU per hour and are for elevations up to 2 000 feet For elevations above 2 000 feet input ratings should be reduced 4 percent for each 1 000 feet above sea leve...

Страница 5: ...ing Instructions 2 Canopy 4 Five 5 sheet metal screws for canopy What you will need for installation TOOLS BUILDING SUPPLIES Phillips screwdriver Square Framing materials Hammer Piping complying with...

Страница 6: ...ing or into prepared framing 2 Plumb gas line Gas connections should only be performed by an experienced licensed certified tradesman 3 Install vent free gas log heater per the instructions provided w...

Страница 7: ...indows or doors Installation must provide adequate ventilation and combustion air DO NOT INSTALL THIS FIREBOX IN A BED ROOM OR BATHROOM Location should be out of high traffic or windy or drafty areas...

Страница 8: ...back wall Figure 4 Clearance and Height Requirements 4 Floor clearance This inner chamber firebox floor must be installed at least 1 above any combustible flooring mate rial such as carpeting or aspha...

Страница 9: ...nit must be installed If a combustible mantel is installed it must meet the clearance requirements as shown in Figure 7A However if lower mantel height is desired see page 14 and Figure 7B for canopy...

Страница 10: ...pth of the enclosure The classification noncombustible material includes but is not limited to stone brick and mortar Noncombustibles are safe to overlay the black painted metal face including radiant...

Страница 11: ...mmodate the fireplace with trim installed is as follows Figure 13 Custom Cabinet Figure 14 Location of Nailing Flanges The fireplace must be installed giving full consideration to the clearance and he...

Страница 12: ...ters in addition to the regulator fitted to the heater to reduce the supply tank pressure to 13 w c maximum Any copper tubing used to supply propane L P G from the tank must be internally tinned Note...

Страница 13: ...he side frames See Figure 15 2 Align the canopy with the holes in the top frame 3 Replace the screws previously removed 4 Tighten side screws Make sure the canopy is level and secure The firebox canop...

Страница 14: ...F 32LCUF R 36LCUFC R 1 Canopy 1 71D0023 71D0023 71D0500 Screen Panel 2 070942 070942 26D4563 3 Screen Rod 2 26D0138 26D0138 26D0132K ACCESSORIES in KITS 1 Standard Brass Canopy 1 BRCU32 BRCU32 BRCU36...

Страница 15: ...or garage space 5 Locate air supply inlet at least 3 away from any applaince vent terminal 6 Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air...

Страница 16: ...lamp or screws See Figure 21 DO NOT remove the cover if the outside air will not be connected WARNING Figure 20 Attaching Outside Air Starting Collar and Insulation Ring to Left Side of Fireplace Figu...

Страница 17: ...l Note If the wall covering is brick or stone use appropriate masonry fasteners If necessary splice the duct Use a model 403 duct connector to splice duct sections Installing model 403 duct connector...

Страница 18: ...18 26D4751 notes...

Страница 19: ...d Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assemb...

Страница 20: ...AUGUST 2008 26D4751 Rev 10 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: