Majestic fireplaces NVCR36R Series Скачать руководство пользователя страница 3

3

Majestic Fireplaces

©

 NVCR Series B-Vent

20001315

This gas appliance should be installed by a qualified in-
staller in accordance with local building codes and with 
current 

CSA B149.1

 Installation codes for Gas Burning 

Appliances and Equipment.
FOR U.S.A. installations follow local codes and/or the 
current National Fuel Gas Code. ANSI Z223.1/NFPA 54.
In the Commonwealth of Massachusetts, all gas fitting 
and installation of this heater shall only be done by a 
licensed gas fitter or licensed plumber.
FOR SAFE INSTALLATION AND OPERATION OF 
YOUR NATURAL DRAFT APPLIANCE, PLEASE NOTE 
THE FOLLOWING:
1.  This appliance gives off high temperatures and 

should be located out of high traffic areas and away 
from furniture and draperies.

2.  Children and adults should be alerted to the hazards 

of the high surface temperatures of this appliance 
and should stay away to avoid burns or ignition of 
clothing.

3.  Children should be carefully supervised when they 

are in the same room as the appliance.

4.  Under no circumstance should this appliance be 

modified. Parts having to be removed for servicing 
should be replaced prior to operating this appliance 
again.

5.  Installation and any repairs to this appliance should 

be carried out by a qualified service person. A 
professional service person should be contacted to 
inspect this appliance annually. Make it a practice to 
have all of your gas appliances checked annually. 
More frequent cleaning may be required due to ex-
cess lint and dust from carpeting, bedding material, 
etc.

6.  Control compartments, burners and air passages in 

this appliance should be kept clean and free of dust 
and lint. Make sure that the gas valve and pilot light 
are turned off before you attempt to clean this unit.

7.  The venting system (chimney) of this appliance 

should be checked at least once a year and if 
needed your venting system should be cleaned.

8.  Keep the area around your appliance clear of 

combustible materials, gasoline and other flam-
mable vapor and liquids. This appliance should not 
be used as a drying rack for clothing, nor should 
Christmas stockings or decorations be hung in the 
area of it.

9.  Under no circumstance should any solid fuels 

(wood, coal, paper or cardboard, etc.) be used in 
this appliance.

10.  The flow of combustion and ventilation air must not 

be obstructed in any way.

11.  Whether the appliance is installed directly on car-

peting, vinyl tile or any combustible material other 
than wood, this appliance must be installed on a 
metal or wood panel extending the full width and 
depth of the appliance.

12.  This appliance requires adequate ventilation and 

combustion air to operate properly.

Description

NVCR36L/R Series are radiant, natural draft appliances 
and use a 6” B-vent system. Do not burn wood or other 
materials in these appliances. Each model is available 
with standing pilot or electronic ignition for use with 
Natural or Propane gas units.
Report to your dealer any parts damaged in shipment.
Adequate combustion and ventilation air must be pro-
vided. The flow of combustion and ventilation air MUST 
NOT be obstructed.
Provide adequate clearances around the air opening 
into the combustion chamber; and adequate accessibil-
ity clearance for servicing and proper operation.
The 6” vent system MUST connect to the appliance and 
terminate out-of-doors in a vertical position and termi-
nate with a B-vent cap.
This appliance must not be connected to a chimney flue 
servicing a separate solid-fuel burning appliance.
A draft hood is an integral part of the appliance. 

General Information

Clearances to Combustibles

Top of unit to ceiling ........................................... 36” (914 mm)
Front of unit to combustibles ............................. 36” (914 mm)
Sides, floor, back, top (dim. to standoffs) ................ 0” (0 mm)
Perpendicular side wall ........................................... 0” (0 mm)
B-vent .................................................................... 1” (25 mm)
Mantel dimensions vary ...............Refer to Page 12, Figure 13 

Proposition 65 Warning:

 Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known to 
the State of California to cause cancer, birth defects 
and other reproductive harm.
California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufac-
turer before installing a television or other electron-
ic device above this fireplace.

f i r e - p a r t s . c o m

Содержание NVCR36R Series

Страница 1: ...ency or the gas supplier Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY If you smell gas 1 Open windows 2 Do not touch...

Страница 2: ...ance 7 Insulating for Cold Climates 7 Installation Framing 8 Gas Line Installation 8 Option for E Models ONLY EB1 Receptacle Hook Up 8 Remote Wall Switch 9 Slide the Appliance in Place 9 Level and Sec...

Страница 3: ...ance should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung in the area of it 9 Under no circumstance should any solid fuels wood coal paper or cardboar...

Страница 4: ...178mm 14 362mm Gas Line Access 41 1054mm Rough Opening Height 12mm 1019mm 36 914mm 21 540mm 497mm 6 172mm 251mm 1 25mm Rough Opening Depth 16mm Recessed Nailing Flange 21 556mm 559mm 10 254mm 12mm 12m...

Страница 5: ...5 5 w c 11 0 w c Maximum Inlet Pressure 14 0 w c 14 0 w c Manifold Pressure 3 5 w c 10 0 w c High Elevations Input ratings are shown in BTU per hour and are certi ed without deration for elevations up...

Страница 6: ...l for cold climate not a requirement for unit operation Termination Cap Storm Collar Pan Flashing Draftstop Outside Air Kit Gas Line Access Electrical Access Screen Grate Hearth Panels Surround Nailin...

Страница 7: ...ailing anges FP800 FP549CR Corner unit nailing flanges 5 3 99 djt Nail Top Standoffs Nail Side Nailing Flanges Fig 4 Adjustable drywall strip nailing anges FP549CR Insulating for Cold Climates When an...

Страница 8: ...re test point therefore it is not necessary to pro vide a 1 8 test point up stream of the control When using copper or ex connector use only ap proved ttings Always provide a union so that gas line ca...

Страница 9: ...g connected gently slide or lift the appliance to the desired location Level and Secure the Appliance If nailing anges are not already installed attach anges with the screws provided Make sure applian...

Страница 10: ...ion See venting installation instructions provided by the B vent manufacturer FP567 NVBR NVBC VENTING RUNS 11 12 97 Venting Runs 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 8 9 10 1 2 3 4 5 6 7 Horiz...

Страница 11: ...sem bly Optional Thermal Vent Damper TVD6 7 Attach the thermal vent damper to the combustion dome with two 2 screws Be sure the tab points down Fig 12 Start the appliance and operate it for approximat...

Страница 12: ...Fig 13a Mantel clearances Top Louvre Assembly Top of Combustion Chamber Bottom of Door Trim CFM146 Ref Mantel Ref Mantel from Top Shelf Depth of Comb Chamber V 14 356 mm A 18 457 mm W 12 305 mm B 16 4...

Страница 13: ...he appli ance will not require purging When lit for the rst time the appliance will emit a slight odor for an hour or two This is due to paint and lubri cants used in the manufacturing process After e...

Страница 14: ...mell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do...

Страница 15: ...ormer Taking care of the Electronic Ignition units is almost identical to taking care of the Standing Pilot models See Maintenance sections on page 16 The hot sur face ignitor is the only component wh...

Страница 16: ...mmend replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the circumstances present Clean glass after rst two weeks of opera tion In...

Страница 17: ...essing Piezo red button 1 8 gap to pilot hood needed All wiring connections Replace Piezo ignitor Thermodisk For air in the lines Thermopile needs a minimum of 325mV Ad just pilot ame height All wirin...

Страница 18: ...nnections between module and pilot operator on gas control Check for 24VAC across PV MV PV terminals on module if voltage is okay Re place gas control if not replace module NOTE if S8600B goes into lo...

Страница 19: ...peci cations prices and discontinue colors and products at any time without notice NVCR36L R Ref Description NVCR36L NVCR36R 1 Log Set Complete 20001416 200014160 1a Log Rear 3043146 3043146 1b Log Fr...

Страница 20: ...tion NVCR36L NVCR36R 9 Screen Rod 7554181 7554181 10 Brick Back 20000792 20000792 11 Side Brick 20000793 20000793 12 Ceramic Panel Outside 20001348 20001348 13 Ceramic Panel Inside 20001347 20001349 1...

Страница 21: ...ol Thermal Vent Damper Description Glass Door Set Bi fold door for front of unit with solid panel on the side Completes connection from air kit to out of doors Electrical box for E models Wireless rem...

Страница 22: ...22 Majestic Fireplaces NVCR Series B Vent 20001315 fire parts com...

Страница 23: ...inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation fire parts com...