![Majestic fireplaces NVCR36R Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/majestic-fireplaces/nvcr36r-series/nvcr36r-series_installation-and-homeowners-operating-manual_4039835012.webp)
12
Majestic Fireplaces
©
NVCR Series B-Vent
20001315
FP568
NVBR/NVBC
12/4/97
See mantel drawing for
shelf-to-surround dimension
Mantel Shelf
Finished Wall
Stud
2 x 4 Finished
Header
Standoff
Seal with
noncumbustible
material ONLY
Surround
Fireplace
Front
Side View
1/2”
2 x 4 Stud
Finished Wall
May be sealed with
concombustible
Fireplace
Front
Top View
FP568
Fig. 14
Fireplace surround clearances.
A B C D E
V
W
X
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01 sta
Mantel Clearances
Fig. 13a
Mantel clearances.
Top Louvre
Assembly
Top of
Combustion
Chamber
Bottom of Door Trim
CFM146
Ref.
Mantel
Ref.
Mantel from Top
Shelf Depth
of Comb. Chamber
V
14” (356 mm)
A
18” (457 mm)
W
12” (305 mm)
B
16” (406 mm)
X
10” (256 mm)
C
14” (356 mm)
Y
8” (203 mm)
D
12” (305 mm)
Z
1
¹⁄₂
” (38 mm)
E
8” (203 mm)
J
F
G
H
I
Mantel
Leg
CFM164a
Mantel Leg Chart
06/22/01 sta
CFM170
DV Builder Front
View
O
N
M
L
K
Ref.
Mantel
Ref. Mantel Leg From Side
Leg Depth
of Comb. Opening
F
14” (356 mm)
K
14” (356 mm)
G
12” (305 mm)
L
12” (305 mm)
H
10” (254 mm)
M
10” (254 mm)
I
8” (203 mm)
N
8” (203 mm)
J
1
¹⁄₂
” (38 mm)
O
1
¹⁄₂
” (38 mm)
Black
Surround
Face
Side of
Combustion Chamber
CFM164
CFM170
Fig. 13b
Combustible mantel leg minimum installation.
f i r e - p a r t s . c o m