Majestic fireplaces NVCR36R Series Скачать руководство пользователя страница 20

20

Majestic Fireplaces

©

 NVCR Series B-Vent

20001315

Contact CFM Corporation for questions concerning 
prices and policies covering replacement parts. Parts 
may be ordered through your Majestic Fireplaces dis-
tributor or dealer. 
You will need the following information when ordering 
replacement parts:

1.  The appliance model number.
2.  The serial number.
3.  A description of the part.

Should you need additional information beyond what 
your dealer can furnish, contact:
 

 

CFM Corporation

 

 

410 Admiral Blvd.

 

 

Mississauga, Ontario

 

 

Canada L5T 2N6

Model and serial numbers are listed on the rating 
plate (located on side of combustion chamber).

Record your model and serial numbers here for 
future reference:

Model # ______________________________

Serial # _______________________________

NVCR36L/R 

(continued)

  Ref.   Description 

NVCR36L 

NVCR36R

 

9.  Screen Rod 

7554181 

7554181

  10.  Brick - Back 

20000792 

20000792

  11.  Side Brick 

20000793 

20000793

  12.  Ceramic Panel - Outside 

20001348 

20001348

  13.  Ceramic Panel - Inside 

20001347 

20001349

  14.  Remote Switch Kit 

3078150 

3078150

  15.  Thermodisk 

20001558 

20001558

  16a.  Valve Nova - Natural 

52677 

52677

  16b.  Valve Nova - LP 

52678 

52678

  17a.  Pilot Orifice - Nova - Natural 

54273 

54273

  17b.  Pilot Orifice - Nova -LP 

54272 

54272

  18.  Piezo Ignitor 

52464 

52464

  19a.  Pilot Assembly - Nova - Natural 

52445 

52445

  19b.  Pilot Assembly - Nova - LP 

52446 

52446

  20.  Electrode Ignitor Nova 

52465 

52465

  21.  Thermocouple Nova 

53373 

53373

  22.  Cable Ignitor 

53194 

53194

  23.  Pilot Tubing 

7549333 

7549333

  24.  Thermopile Nova 

51827 

51827

  25a.  E. Valve - Natural (SIT) 

57884 

57884

  25b.  E. Valve - LP (SIT) 

57883 

57883

  26a.  E. Pilot Assembly - Natural (SIT Pilot 4 way) 

54219 

54219

  26b.  E. Pilot Assembly - LP (SIT Pilot 4 way) 

54221 

54221

  27.  Sensing Electrode 

57885 

57885

  28.  Transformer 

7522409 

7522409

  29.  Ignition Device - Honeywell 

20000005 

20000005

f i r e - p a r t s . c o m

Содержание NVCR36R Series

Страница 1: ...ency or the gas supplier Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY If you smell gas 1 Open windows 2 Do not touch...

Страница 2: ...ance 7 Insulating for Cold Climates 7 Installation Framing 8 Gas Line Installation 8 Option for E Models ONLY EB1 Receptacle Hook Up 8 Remote Wall Switch 9 Slide the Appliance in Place 9 Level and Sec...

Страница 3: ...ance should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung in the area of it 9 Under no circumstance should any solid fuels wood coal paper or cardboar...

Страница 4: ...178mm 14 362mm Gas Line Access 41 1054mm Rough Opening Height 12mm 1019mm 36 914mm 21 540mm 497mm 6 172mm 251mm 1 25mm Rough Opening Depth 16mm Recessed Nailing Flange 21 556mm 559mm 10 254mm 12mm 12m...

Страница 5: ...5 5 w c 11 0 w c Maximum Inlet Pressure 14 0 w c 14 0 w c Manifold Pressure 3 5 w c 10 0 w c High Elevations Input ratings are shown in BTU per hour and are certi ed without deration for elevations up...

Страница 6: ...l for cold climate not a requirement for unit operation Termination Cap Storm Collar Pan Flashing Draftstop Outside Air Kit Gas Line Access Electrical Access Screen Grate Hearth Panels Surround Nailin...

Страница 7: ...ailing anges FP800 FP549CR Corner unit nailing flanges 5 3 99 djt Nail Top Standoffs Nail Side Nailing Flanges Fig 4 Adjustable drywall strip nailing anges FP549CR Insulating for Cold Climates When an...

Страница 8: ...re test point therefore it is not necessary to pro vide a 1 8 test point up stream of the control When using copper or ex connector use only ap proved ttings Always provide a union so that gas line ca...

Страница 9: ...g connected gently slide or lift the appliance to the desired location Level and Secure the Appliance If nailing anges are not already installed attach anges with the screws provided Make sure applian...

Страница 10: ...ion See venting installation instructions provided by the B vent manufacturer FP567 NVBR NVBC VENTING RUNS 11 12 97 Venting Runs 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 8 9 10 1 2 3 4 5 6 7 Horiz...

Страница 11: ...sem bly Optional Thermal Vent Damper TVD6 7 Attach the thermal vent damper to the combustion dome with two 2 screws Be sure the tab points down Fig 12 Start the appliance and operate it for approximat...

Страница 12: ...Fig 13a Mantel clearances Top Louvre Assembly Top of Combustion Chamber Bottom of Door Trim CFM146 Ref Mantel Ref Mantel from Top Shelf Depth of Comb Chamber V 14 356 mm A 18 457 mm W 12 305 mm B 16 4...

Страница 13: ...he appli ance will not require purging When lit for the rst time the appliance will emit a slight odor for an hour or two This is due to paint and lubri cants used in the manufacturing process After e...

Страница 14: ...mell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do...

Страница 15: ...ormer Taking care of the Electronic Ignition units is almost identical to taking care of the Standing Pilot models See Maintenance sections on page 16 The hot sur face ignitor is the only component wh...

Страница 16: ...mmend replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the circumstances present Clean glass after rst two weeks of opera tion In...

Страница 17: ...essing Piezo red button 1 8 gap to pilot hood needed All wiring connections Replace Piezo ignitor Thermodisk For air in the lines Thermopile needs a minimum of 325mV Ad just pilot ame height All wirin...

Страница 18: ...nnections between module and pilot operator on gas control Check for 24VAC across PV MV PV terminals on module if voltage is okay Re place gas control if not replace module NOTE if S8600B goes into lo...

Страница 19: ...peci cations prices and discontinue colors and products at any time without notice NVCR36L R Ref Description NVCR36L NVCR36R 1 Log Set Complete 20001416 200014160 1a Log Rear 3043146 3043146 1b Log Fr...

Страница 20: ...tion NVCR36L NVCR36R 9 Screen Rod 7554181 7554181 10 Brick Back 20000792 20000792 11 Side Brick 20000793 20000793 12 Ceramic Panel Outside 20001348 20001348 13 Ceramic Panel Inside 20001347 20001349 1...

Страница 21: ...ol Thermal Vent Damper Description Glass Door Set Bi fold door for front of unit with solid panel on the side Completes connection from air kit to out of doors Electrical box for E models Wireless rem...

Страница 22: ...22 Majestic Fireplaces NVCR Series B Vent 20001315 fire parts com...

Страница 23: ...inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation fire parts com...

Отзывы: