background image

2

Majestic Fireplaces

®

 BR/BC Series

7412944

BR36 / BR42
BC36 / BC42

Listed

UL 127 / ULC-S610

Standard for Factory Built Fireplaces

Safety Information

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.
IMPORTANT: 

Read all instructions and warnings carefully before starting installation.  Failure to 

follow these instructions may result in a possible fire hazard and will void the warranty.

Description

The BR/BC Series fireplaces are solid fuel, woodburning 
fireplaces. The BR36/42 (Builder Radiant) is a clean-face 
fireplace and the BC36/42 (Builder Circulating) unit has 
fixed grilles.

Precautions

CFM Corporation fireplaces and component parts have 
been highly tested and will operate safely when installed 
in accordance with instructions provided in this manual. 
Carefully read and understand all instructions 

before

 

beginning installation.
If you notice any damage to fireplace or component parts, 
immediately report damage to your Majestic Fireplaces 
dealer.
Only use CFM Corporation components or the warranty 
will be voided and a fire hazard may be created.
CFM Corporation warranty will be voided by and CFM 
Corporation disclaims any responsibility for the following 
actions:

• 

Installation by any other than a qualified install-
er, preferably NFI or WETT (Canada) certified.

• 

Installation of any damaged fireplace or chim-
ney component;

• 

Modification of fireplace, chimney assembly or 
any component parts thereof; 

(except for chase 

flashings as detailed in Chimney Top installation 
instructions).

• 

Installation other than as instructed by CFM 
Corporation; or

• 

Installation and/or use of any component part 
not manufactured or approved by CFM Corpo-
ration in combination or assembly with a Majes-
tic Fireplaces fireplace system, notwithstanding 
any independent testing laboratory or other 
third party approval of such component parts 
or accessory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in 
compliance 

before 

installing the fireplace.

Fireplaces must be vented to the out-of-doors.

Do not obstruct or modify air inlets/outlets in any 
manner. 

Do not install combustible materials on any of the 
black fireplace surround.
Burn only solid wood fuel or gas logs.
Do not install a solid fuel burning insert or other 
products not specified for use with this fireplace.

Proposition 65 Warning: 

Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known to 
the State of California to cause cancer, birth defects 
and other reproductive harm.
California Health & Safety Code Sec. 25249.6

Drafts

The fireplace should not be located in areas that create 
drafts (ie: frequently opened doors and central heating air 
inlets/outlets) that hamper the normal flow of air into the 
fire.

Gas Logs

If you plan to install a gas log, the gas line should be 
installed 

before

 framing the fireplace. The gas line must 

be installed by a certified gas line installer.

Safety Information . . . . . . . . . . . . . . . . . .  2
Specifications and Framing   . . . . . . . . . .  3
Parts Identification  . . . . . . . . . . . . . . . . .  5
Chimney Requirements  . . . . . . . . . . . . .  6
Planning Information . . . . . . . . . . . . . . . .  7
Installation   . . . . . . . . . . . . . . . . . . . . . . .  8
Replacement Parts . . . . . . . . . . . . . . . .  19
Accessories   . . . . . . . . . . . . . . . . . . . . .  20

Table of Contents

Содержание BC42

Страница 1: ...s Woodburning Fireplace For Models BR36 BR42 BC36 BC42 DO NOT DISCARD THIS MANUAL Retain for future use 7412944 4 07 Rev 21 For use in U S Canada Underwriter s Laboratories Report No MH6018 Homeowner s Installation and Operating Manual ...

Страница 2: ...installation instructions Installation other than as instructed by CFM Corporation or Installation and or use of any component part not manufactured or approved by CFM Corpo ration in combination or assembly with a Majes tic Fireplaces fireplace system notwithstanding any independent testing laboratory or other third party approval of such component parts or accessory Any such action may possibly c...

Страница 3: ... 1041mm 8 Dia 203mm 8 2 2 m m If elbows are offset to the back of the unit chase depth will be 22 575mm Fig 2 BC36 Series specifications and framing BC36 Series Woodburning Fireplace Circulating Model 1 6 m m 13mm 36 914mm 34 880mm 40 1016mm 502mm 64mm 902mm 533mm 197mm 191mm Recessed Nailing Flange FP527 BC36 SPECS 10 28 98 11 Dia 279mm Rough Opening Width 41 Rough Opening Height Rough Opening Dep...

Страница 4: ... Air Gas Line Access Electrical Access 1194mm 8 Dia 203mm 8 9 5 m m If elbows are offset to the back of the unit chase depth will be 22 575mm BR42 Series Woodburning Fireplace Fig 3 BR42 Series specifications and framing 42 1067mm 46 1168mm 36 930mm 1 6 m m 13mm 502mm 533mm 197mm 191mm Gas Line Access Recessed Nailing Flange FP546 BR42 SPECS 10 28 98 11 Dia 279mm Rough Opening Width 47 Rough Openin...

Страница 5: ...Collar Pan Flashing Draftstop Standoff Surround Damper Control Gas Line Knockout both sides Screen Grate Firebox Metal Safety Strips 1 2 or 3 pieces Outside Air Cover Plate Electrical Access Gas Line Access both sides Nailing Flange Ceiling Level Firestop Batt Insulation cut our around firestop A B C FP1531 hearth dimensions 9 04 djt Front Width Back Width Depth A B C BR BC36 33 19 15 845 mm 499 mm...

Страница 6: ...2 Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a structural framing member The offset first elbow of any pair does not have straps FP269 C The chimney cannot be more than 30 45 in Canada from the vertical plane in any installation D The maximum length of the...

Страница 7: ...ning a chimney system it is important to know 1 The height of a chimney is measured from the hearth to the exit point on the termination 2 A chimney cannot be offset more than 30 from a vertical plane 3 A chimney may run straight up or it may be neces sary to offset it to avoid obstructions 4 The maximum length of an angled run total chimney system is 20 6 m 5 No more than 2 offsets 4 total 30 elb...

Страница 8: ...ocation or how the chimney system should be run contact your Majes tic Fireplaces dealer for assistance If you live in a cold climate it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible Insulate base of fireplace with a noncombustible insulation rated for a minimum of 300 F Insulating is very important for outside wall...

Страница 9: ... fan kit Remove knockout in the center of the back of the EB1 and install listed cable clamps Feed electrical wire through listed cable clamp leaving approximately 6 152 mm of wire exposed through the EB1 Se cure listed cable clamp to the wire Attach white wire from power source to one 1 wire of receptacle and secure with nut Attach black wire from power source to the other wire of receptacle and ...

Страница 10: ...requirement at attic level Offset Installation In order to clear an obstruction it may be necessary to offset chimney from vertical This is accomplished by using CFM Corporation elbows Use the 30 Offset Elbow table on Page 6 to determine proper offset and parts required Each offset requires two 2 elbows The second elbow is equipped with support straps It is very important to install the second elb...

Страница 11: ...s strips provided with the fireplace Note Safety strips are not required over noncombusti ble floors where all supports at the base of the fireplace are noncombustible Four 4 nailing flanges are supplied with the fireplace found on the fireplace hearth To level the box and secure it firmly in place remove the nailing flanges from the hearth and install at the sides of the fireplace as shown in Figure 15 In...

Страница 12: ...or ceiling thickness up to 8 203mm When combined thickness of ceiling material ceiling joists and flooring material exceeds 8 203mm adjustments must be made in framing to assure that minimum air spaces to chimney are maintained Proper Firestop Spacer Installation Figure 18 shows different installation procedures for both an area that is an attic and an area that is not an attic If the area above th...

Страница 13: ...Centerpoint On Roof Use same procedure detailed in locating center point of the flue system Drive a nail up through roof at the center point This will determine center point on outside of the roof Cut and Frame Roof Hole Size of roof hole varies with the type of chimney termination installed Refer to installation instructions provided with the chimney termination to find correct size of roof hole Th...

Страница 14: ...ll with material of your choice Do not install a combustible mantel shelf less than 12 305mm from the top of the fireplace opening for radiant models and 12 305mm from top of grille opening for circulating models Do not install a mantel face plate less than 6 159mm from top of fireplace opening for radiant models and 6 159mm from top of grille opening for circulating models Fig 22 If a combustible m...

Страница 15: ... 12 305mm Min 1 38mm 6 159mm Min 12 305mm Max 12 305mm Min 1 38mm 6 159mm Min Mantel Clearance Radiant Model No Noncombustible Facing Material Combustible Mantel and Trim Finished Wall Header Standoff Noncombustible Material Radiant Surround Face Fireplace Opening Minimum width from top of sur round to bottom of screen rail Combustible Mantel and Trim Finished Wall Header Standoff Noncombustible M...

Страница 16: ...3 Secure the hearth extension to the floor to prevent shifting using trim molding or other similar means at three 3 outer edges Seal crack between the fireplace hearth and hearth extension with a noncombustible material Figs 23 and 25 Minimum Wall Clearances WITH Noncombustible Surround Facing WITHOUT Noncombustible Surround Facing Minimum Hearth Extension Dimensions for On Site Construction G H G J...

Страница 17: ...inch Units of K BTU SQ FT HR F IN Thickness of Listed Material FP533ADD Addendum 6 1 99 djt 8 4 99 changed 2 to 1 one inch to 1 2 inch djt FP533ADD Fig 24 Hearth extension material factors FP550 Fig 25 Sealing gaps FP550 BR BC SEALING DETAILS 9 29 97 Wall Covering Noncombustible Decorative Facing Noncombustible Decorative Covering Seal all cracks between fireplace surround and wall materials with ...

Страница 18: ... small chisel and hammer carefully tap around the knockout until it loosens and falls out Install 1 2 inch certified gas pipe through opening After gas pipe installation is complete use insulation that was removed from gas line tube to repack space around the pipe Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube Note Gas pipe shou...

Страница 19: ...102 or 20007495 3032102 or 20007497 6c Firebrick Rt Side 3030160 or 20007492 3030160 or 20007492 6d Firebrick Lt Side 3030104 or 20007493 3030104 or 20007493 7 Top Brick Retainers three per fireplace 3030172 3030172 8 Cable Clips four per fireplace 7512135 7512135 9 Hearth Pan Cover BC Only 3031104 3031104 10 Outer Collar Assembly SK8 Chimney 3030143 3030143 11 Nailing Flange Bag of 4 w screws 22531...

Страница 20: ...ided by the owner s insurance Accessories Contact your Majestic Fireplaces distributor or dealer for finishing Marble and Mantels available in a wide selection of styles Glass Door Standard Bi Fold door set Brushed Brass finish 36GDKBB BR BC36 42GDKBB BR BC42 Black finish 36GDKBK BR BC36 42GDKBK BR BC42 Polished Brass finish 36GDKDP BR BC36 42GDKDP BR BC42 Pewter finish 36GDKS BR BC36 42GDKS BR BC42 Fa...

Страница 21: ...chimney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low profile pyramid style chimney cap used to PTLSK8 terminate chimney through a chase Includes adapter Flashing not included Chase Top Housing Square chimney cap used to terminate chimney SLTSK8 through a chase Terra Cott...

Страница 22: ...ation Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 Chimney Elbows Provides 45 offset and return For Canadian SK845 2 installations only For use with SK8 chimney only Maximum use of 2 or 1 pair Canada Model Number Description Component Chimney Components...

Страница 23: ...ce installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed or serviced by a qualified installer preferably NFI or WETT Canada certified and according to the installation instructions furnished with the Fireplace and operated at all times under normal condi tions use and service according to the operative instructions furnished with ...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation ...