BFC36 Balanced Flue Heat-Circulating Fireplace

7412647

Chimney Supports

The chimney system is supported by the fireplace for 
vertical chimney heights less than 30’ (9m) above the 
hearth. Chimney supports are required if the vertical 
height exceeds 30’ (9m).  Locate chimney supports 
at ceiling holes or other structural framing at 30’ (9m) 
heights. Spacing between chimney supports 

must not

 

exceed 30’ (9m).  Use Chimney Support Model TCS8A.  

(NOTE:  The TCS8A cannot be mounted directly to 
the fireplace.) 

 Support provided by elbow straps fulfills 

the support requirement only if they are spaced as pre-
viously described. (A chimney support is 2

¹⁄₂

" (64mm) 

long when installed.)
Angled chimney runs require a support every 6’ 1.8m) 
in addition to the elbow straps. Chimney supports are 
used for this function. (Fig. 6) 

FP284a

TCS8A

8/21/00 

Chimney Sup-

port Strap

TCS8A

FP284a

Fig. 6

  Chimney support installation.

Chase Installation

A chase is a vertical box-like structure which encloses 
the fireplace and/or chimney. Chases are typically built 
on the outside of the house with fireplace opening cut 
into the outer wall of a room.  (Page 4, Fig. 2)
If you need help in determining fireplace location or how 
the chimney system should be run, contact your Ver-
mont Castings, Majestic Products dealer for assistance.

Installation

Insulating Fireplace Enclosure 

for Cold Climates

If you live in a cold climate, it is not required but 

highly recommended

 that you insulate fireplace 

enclosure to eliminate cold air penetration as much 
as possible.
Insulate base of fireplace with a noncombustible 
insulation rated for a minimum of 300°F.  Insulating 
is 

very important

 for outside wall installations over 

a concrete slab. If fireplace is installed on a platform, 
insulation should be placed on top of the platform 

before 

fireplace is set. (Fig. 7)

When a fireplace is installed in a chase or on a 
outside wall, enclosure should be treated like any 
outside wall in a home. Insulation should be installed 
on the inside wall as well as the outside wall(s). In 
a chase, it is also a good idea to install a firestop at 
the first ceiling level above the fireplace and enclose 
the chase with sheeting material. Insulation may 
then be installed above sheeting material to assure 
the space around the fireplace is totally protected. 
(Fig. 2)
When installing the chimney, 

DO NOT

 caulk be-

tween outer pipe and firestop. It is vital that some air 
be allowed to flow through this very thin gap.

CAUTION:  When installing a fireplace in an insu-
lated enclosure, be sure all required air spaces 
are maintained. (Page 13, Fig. 17)

Содержание BFC36

Страница 1: ...Closed Combustion Heat Circulating Fireplace Model BFC36 For use in the U S Canada Underwriter s Laboratories Report No MH6018 DO NOT DISCARD THIS MANUAL Retain for future use 7412647 8 08 Rev 15 Hom...

Страница 2: ...n combination or assembly with a MHSC re place system notwithstanding any indepen dent testing laboratory or other third party approval of such component parts or acces sory Any such action may possib...

Страница 3: ...ge 647 BFC36 specs 8 18 00 djt 13 Dia 343mm Rough Opening Width 43 Rough Opening Height Rough Opening Depth Gas Line Access 51 1297mm 51 1297mm 1 8 3 4 m m 197mm 23 584mm 610mm 624mm 39 997mm 246mm 35...

Страница 4: ...ftstop Standoff Surround Trim Ledge Standoff Glass Door Romex Pigtail Gas Line Access Knock out Each Side Air Inlet Basket Grate Bottom Grille Metal Safety Strip s Shown not inplace 1 2 or 3 pieces Na...

Страница 5: ...et of angled run of chimney Chimney supports are required for every 30 feet and 60 feet of vertical chimney height above the hearth Determine the offset distance of your chimney arrangement from the c...

Страница 6: ...r 2 total 45 elbows in Canada per replace may be used 6 A guy wire stabilizer is required for chimneys extend ing more than 6 1 8m above a roof line The Ten Foot Rule Major U S building codes specify...

Страница 7: ...ow the chimney system should be run contact your Ver mont Castings Majestic Products dealer for assistance Installation Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate i...

Страница 8: ...ire nuts must be tight NOTE Check local building codes to determine if junction box is required at the romex pigtail house wire connection Also check junction box and speed control SCVS installation i...

Страница 9: ...ut Check to see where existing ceiling joists and other possible obstructions are located i e wiring plumbing etc If necessary re position chimney and or replace to avoid obstructions Cutting the Hole...

Страница 10: ...in front of the replace This Z shaped safety strip is not provided but must be fabricated of metal with each horizontal leg at least 1 38mm wide and equal in length to the metals strips provided with...

Страница 11: ...ness up to 8 203mm When combined thickness of ceiling material ceiling joists and ooring material exceeds 8 203mm adjustments must be made in framing to assure that minimum air spaces to chimney are m...

Страница 12: ...ombustible surfaces Combustible surfaces include burnable materials such as ceiling members joists ooring combustible insulation and roof structures WARNING Do not pack required air spaces with insula...

Страница 13: ...e not a substitute for local building codes You must check your local building codes to determine speci c requirements for your city or state NOTE Other building materials may be required in addition...

Страница 14: ...mantel clearances 12 from top of grille opening 6 from top of grille opening Face Plate FP531b mantel clearances 9 03 djt 12 305mm Max 12 305mm Min 1 38mm 6 159mm Min Fig 19 Mantel clearance Combustib...

Страница 15: ...ct hearth extension material Fig 21 Secure the hearth extension to the oor to prevent shifting using trim molding or other similar means at three 3 outer edges Seal crack between the replace hearth an...

Страница 16: ...nits of K BTU SQ FT HR F IN Thickness of Listed Material FP533ADD Addendum 6 1 99 djt 8 4 99 changed 2 to 1 one inch to 1 2 inch djt FP533ADD Fig 22 Hearth extension material factors Example of Determ...

Страница 17: ...pipe should not come in contact with any wood structures until it has reached a point at least 1 25 mm away from replace side BTU input of a gas appliance installed in replace should be rated less th...

Страница 18: ...cription BFC36 1 Top Grille Painted 3126160 2 Bottom Grille Painted 3126160 3 Grate Assembly 7579218 4 Left Door Assembly Complete 30004361 5 Right Door Assembly Complete 30004362 6 Rear Firebrick 235...

Страница 19: ...c Glass Panel two per replace 30004352 21 Flat Gasket 3 4 Wide two per replace 20013997 22 Knob two per replace 1600657 23 Bushing four per replace 1201895 24 Pan Hd PH 1 4 20 x 1 Black two per replac...

Страница 20: ...uch must be operat ed only with MHSC approved components If you use an unapproved component to make any modi cations you may create a possible re hazard and will void the MHSC warranty In addition suc...

Страница 21: ...ing is not included TT200C Adapter Kit TT8CB is required Chase Top Housing Used with chase terminations to prevent rain entry FL88 8 ue Contemporary Flashing 8 6 12 with 8 ue Required for Contemporary...

Страница 22: ...22 BFC36 Balanced Flue Heat Circulating Fireplace 7412647...

Страница 23: ...ressure dif ferentials produced by wind Broken glass components Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this replace to be in compliance with your loca...

Страница 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: