MP1800 Router Install Manual V1
.2
Step 1: Connect the phone cable to the RJ11/RJ45 interface of
1VOS/2VOS and the other side to the small switch or external distribution
box.
Step 2: During the call, pay attention to the indicator on the back panel of
the 1VOS/2VOS card. The indicator of each channel should be on during
the call and the Active light of the slot on the front panel should also be on.
Otherwise, contact the agent.
Note
When connecting, pay attention to the ID on the interface, avoiding
inserting into other interface and damaging the module or router host.
Connect 1ST Module Interface Cable
Connect the cables of the 1ST module as follows:
Step 1: Insert the RJ45 plug of the 1ST module interface cable to the
RJ45 jack;
Step 2: Connect the other side of the interface cable to the corresponding
device wire.
Connect 8AX Module Interface Cable
Connect the cables of the 8AX module as follows:
Step 1: Connect the DB60 plug of the 8AX module interface cable to the
jack of the module. Pay attention to the positive and negative directions of
the connector. Tighten the knob to fix the cable on the jack of the 8AX
module.
Step 2: Connect theRJ45 interface of the cable to the corresponding
device.
Connect ADSL Module Interface Cable
Step 1: Connect the RJ11 plug of the ADSL module interface cable to the
RJ11 jack.
Step 2: Connect the other side of the RJ11 plug to the corresponding
device.
Maipu Confidential & Proprietary Information
Page
49
of
55