MP2600D, MP2600C & MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information
Page
21
of
52
For the connection of eight asynchronous interfaces and DTE, we adapt
connected Ethernet cable with DCE RJ45-DB25. For the connection of eight
asynchronous interfaces and MODEM, we adapt connected Ethernet cable
with DTE RJ45-DB25.
Advanced optical/electric isolation interface protection technology - We
adapt advanced optical/electric isolation interface protection technology to
make the isolation effective and prevent the loopback risk.
Slot
MP2600D/MP2600C/MP1700E series router has two slots: SLOT0 and
SLOT1. SLOT0 is MIM module slot, and it supports Ethernet interface
module, sync/async interface module, asynchronous interface module,
E1/CE1 interface module, U interface module, ST interface module,
baseband MODEM interface module, frequency band MODEM module,
VOP/VOS module. It is compatible with MP17XX
,
MP26XX series router
function module.
SLOT1 is voice card slot for VOP/VOS card module, which can access any
telephone via dialup or second dialup; you can realize free phone call in
network by IP network.