18.0 Fault Finding
© Baxi Heating UK Ltd 2011
Gas at burner
Ensure gas is on and purged
Replace PCB
Replace gas valve
PCB - X3 connector is 230V AC across
terminals 1 & 2
YES
NO
NO
F
Replace PCB
G
Check and correct if necessary
1. Ignition electrode and lead
2. Electrode connection
3. Spark gap and position
voltage at PCB - X2 connector is
110V AC across terminals 2 & 5
(Note: from multimeter connect
‘common’ to 2 & ‘volts’ to 5)
Check wiring
YES
NO
Replace igniter
YES
Check and correct the connection of the
tube between the venturi and gas valve
1.
2.
Check and correct if necessary
1. The mechanical set of the gas valve
(CO2 values - see instruction)
2. Flame sensing electrode and lead connections
3. Flame sensing electrode position
Flame current should be more than 0.5
μ
A
Replace PCB
Replace PCB
YES
YES
Replace flame sensing electrode
NO
Check the gas supply pressure:
For Natural Gas MINIMUM 17 mbar
I
Replace safety thermostat
YES
NO
Overheat thermostat operated or
faulty, i.e. continuity across
thermostat terminals
Allow to cool. Continuity
across thermostat terminals
more than 1.5 ohm
2.
1.
H