4.0 Fault Indication

7

© Baxi Heating UK Ltd 2011

4.1

Fault Indication

1. Your Main Combi 24 HE has three neon indicators. The
upper two function as boiler on and fault indicators.

2. Depending on the nature of the fault the upper two neons
will illuminate, go off or flash.

3. There are five possible combinations, each indicating one
or more fault conditions. These are described below.

A

The flue or flue terminal is blocked or obstructed in some
way, or there is an internal fault.

If there is no external blockage of the flue that can be easily
removed contact your Installer or Service Engineer.

B

The circulating pump is faulty or the system pressure has
dropped. Check the system pressure (see page 7). If the
pressure is in the normal range a pump fault is indicated.
Contact your Installer or Service Engineer.

C

A fault on the boiler temperature sensor is indicated. Contact
your Installer or Service Engineer.

D

The primary system or the boiler has overheated. Allow the
boiler to cool. Turn the selector switch fully anti-clockwise
against the spring pressure to the ‘Reset’ position and hold for
at least 2 seconds.

If this occurs repeatedly contact your Installer or Service
Engineer.

If the boiler does not relight after resetting it is possible that
the flue has overheated. Contact your Installer or Service
Engineer.

E

The burner has failed to light, or incomplete lighting of the
burner has occurred. Turn the selector switch fully anti-
clockwise against the spring pressure to the ‘Reset’ position
and hold for at least 2 seconds.

If this occurs repeatedly contact your Installer or Service
Engineer.

If the boiler does not relight after resetting blockage of the
condensate drain or trap has occurred. Contact your Installer
or Service Engineer.

Burner On

Flame Failure

Power On

Off

Fast Flashing (2 every second)

On

A

Burner On

Flame Failure

Power On

Off

Slow Flashing (1 every 2 seconds)

On

B

Burner On

Flame Failure

Power On

Slow Flashing (1 every 2 seconds)

Slow Flashing (1 every 2 seconds)

On

C

Burner On

Flame Failure

Power On

Slow Flashing (1 every 2 seconds)

On

On

D

Burner On

Flame Failure

Power On

Off

On

On

E

Reset Position

Supplied by HeatingSpares247.com

Содержание Combi 24 HE

Страница 1: ...UK Ltd 2011 User s Guide and Important Warranty Information Combi 24 HE Please keep these instructions in a safe place If you move house please hand them over to the next occupier Supplied by Heating...

Страница 2: ...nder Copyrights Designs and Patents Act 1988 Applications for the copyright owner s permission to reproduce or make other use of any part of this publication should be made giving details of the propo...

Страница 3: ...ure Range 35 65 C Power On Indicator The indicator will illuminate when there is power to the boiler Flame Failure Indicator The indicator will illuminate when the burner has not fired Burner On Indic...

Страница 4: ...switched on Reset Power On Indicator Burner On Flame Failure Power On Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in the GREEN secti...

Страница 5: ...ough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and contr...

Страница 6: ...5 If the pressure falls below 0 5 this may indicate a leak on the central heating system Fig 2 3 2 To Repressurise the System 1 The procedure is for the optional filling loop kit when fitted However e...

Страница 7: ...ol Turn the selector switch fully anti clockwise against the spring pressure to the Reset position and hold for at least 2 seconds If this occurs repeatedly contact your Installer or Service Engineer...

Страница 8: ...so sufficient for routine maintenance However a clearance of 20mm is required if it is necessary to remove the secondary heat exchanger This should be considered when siting the appliance and in the e...

Страница 9: ...ents for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0051 Product Production certified by Notified Body 0086 For GB IE onl...

Страница 10: ...7 0 Notes 10 Baxi Heating UK Ltd 2011 Supplied by HeatingSpares247 com...

Страница 11: ...ing their taps to the right towards the wall Fig 7 3 Call your Installer or Service Engineer as soon as possible If you smell gas Do not operate light switches Do not operate any electrical equipment...

Страница 12: ...ould have the following information to hand 1 boiler serial number see opposite 2 boiler make and model number 3 Your installer name and address details 4 Proof of purchase if you do not have the boil...

Отзывы: