Mahr GmbH • Millimar C1202

!

 Forfeiture of warranty

Service work caused by viruses that were introduced via a network connection or other data 

carrier, are generally excluded from warranty services.

Storage temperatures below -10°C or above +50°C and relative humidity levels above 85% 

will invalidate the warranty for the instrument.

 Safety information

This instrument complies with the relevant safety regulations. It was dispatched from our 

production facility in a good condition and perfect working order. However, failure to follow 

the instructions given below can cause personal injury or death.

1.    Before you connect up and use the measuring instrument for the first time, please read 

the accompanying documentation.

 

 Follow the safety precautions detailed in the quick guide and operating instructions.

2.    Keep the documentation close to the measuring instrument ready for quick reference.

3.    Follow all safety precautions, accident prevention regulations and internal company 

rules and guidelines. If necessary you should request further information from your 

company safety officer.

4.    Before connecting up this measuring instrument, please check the local mains supply 

voltage to ensure that it is within the working range of the AC adaptor (100 V - 240 V, 

50 Hz - 60 Hz).

 

 If they do not match, this measuring instrument must not be connected under any 

circumstances!

5.    The instrument may only be connected to a grounded power socket which complies 

with the regulations of the local power supply company.

 

 This also applies to any extension cables that are used.

6.    Only use original and intact AC adapters.

7.    When connecting inductive probes, ensure that the plugs are firmly screwed onto the 

connection sockets.

8.    Do not drop the instrument and make sure it is positioned securely.

9.    Do not operate the instrument in areas where there is a risk of explosion and do not 

expose it to direct sunlight!

10.    Do not clean the membrane keypad with solvent-based cleaning agents.

11.    The instrument must not be opened.

12.    The test and measuring equipment, for which the Millimar is used, are subject to 

inspection equipment monitoring.

 

 For this reason, regular inspection equipment monitoring performed by either the user 

or Mahr Service must ensure compliance with the specified error limits for the test and 

measuring equipment.

Содержание Millimar C 1202

Страница 1: ...ompact length measuring instrument 3722972 Millimar C 1202 Quick guide Valid from firmware version 1 0 0 0 Mahr GmbH Carl Mahr Stra e 1 37073 G ttingen Tel 49 551 7073 0 info mahr com www mahr com 102...

Страница 2: ...bol can cause inaccurate results and lead to equipment damage Introduction Permitted uses The Millimar C 1202 is an electronic length measuring and evaluation instrument for use in production Dependin...

Страница 3: ...your company safety officer 4 Before connecting up this measuring instrument please check the local mains supply voltage to ensure that it is within the working range of the AC adaptor 100 V 240 V 50...

Страница 4: ...liability will be accepted for damages caused by other usage or as a result of the incorrect application of this measuring instrument Should your measuring task not be solved with this measuring instr...

Страница 5: ...h dual function 13 1 5 3 Mode display for master measurement 14 1 5 4 Ports 14 2 Initial commissioning applying basic settings 2 1 Switching on 15 2 2 Selecting the display language 15 2 3 Setting the...

Страница 6: ...6 Mahr GmbH Millimar C1202 1 3 2 4 1 Delivery and connections 1 1 Unpacking...

Страница 7: ...7 Mahr GmbH Millimar C1202 microSD B A 5 6...

Страница 8: ...B A 1 2 Scope of delivery Slot for Micro SD memory card Scope of delivery Millimar C 1202 Power supply unit with inter changeable adapter Bus termination module Micro SD memory card Quick guide Bus t...

Страница 9: ...e probes 5331122 Millimar N 1702 U Module for 2 inductive probes 5331125 Millimar N 1702 M HR Module for 2 inductive probes 5331161 Millimar N 1702 Vss Module for 2 incremental probes 5331150 Millimar...

Страница 10: ...sequential Hold down Toggle function Reset max min memory sequential Hold down Toggle function Set zero point parallel Hold down Toggle function Reset max min memory parallel Hold down Toggle function...

Страница 11: ...ion entry Cancel submenu entry Select item Deselect item Save settings to memory card Delete file from memory card Time controlled measuring mode Start measurement Pause measurement Stop measurement R...

Страница 12: ...5 1 Display and operating keys Display Operating keys Scale Master measurement active Warning limit Measured value Tolerance limit Unit Measuring channel active Scale end value Angle in degrees Featu...

Страница 13: ...o functions Pressing the key for longer than two seconds toggles the function Parallel mode Active function Second function Increase scale resolution Reduce scale resolution Hand select feature Start...

Страница 14: ...feature at which the hand is pointing Sequential mode Master measurement is performed for the feature at which the hand is pointing Hand switches automat ically to next feature The master measurement...

Страница 15: ...nstrument and mains socket Press the ON OFF key The following appears on the display Start screen 2 3 Setting the measurement unit Select the relevant measuring unit with or Confirm entry by pressing...

Страница 16: ...uring probe Connect the measuring probe to probe input C1 2 5 Selecting the probe type Press the ON OFF key Menu appears Select Setup 3 with or and Select submenu Probe type C1 with or Select using 4...

Страница 17: ...point before the first measurement To do this use the setup mode that indicates the raw value or absolute value of the probe Select the relevant measuring probe type using or See Technical Data in th...

Страница 18: ...submenu with Confirm entry with 4 key or exit sub menu with key One or two measuring channels will appear Depends on N 1700 module used The value displayed is the direct value from the measuring senso...

Страница 19: ...e set to master value with key Master value 0 2 8 Switching OFF The measuring screen must be ac tive to switch off the C1202 using the ON OFF key Press ON OFF key for at least 2 sec onds The instrumen...

Страница 20: ...20 Mahr GmbH Millimar C1202...

Отзывы: