Mahr GmbH • Millimar C1202

Dear customer,

Thank you for choosing a product by Mahr GmbH. We kindly request that you follow the instructions 

below to ensure the long-term precision of your instrument.

We operate a policy of continuous improvement and are constantly developing our products. Therefore, 

it is possible that there may be slight differences between the text and illustrations in this document and 

the instrument in your possession, especially with regard to type designations. We reserve the right to 

make changes to the design and scope of supply, the right to undertake further technical developments, 

and all rights relating to translation of this documentation.

© by Mahr GmbH

The following symbols are used in these operating instructions:

  General information

!

 Caution

  Caution, hazard

Failure to follow instructions marked with this symbol can cause inaccurate results and lead to 

equipment damage.

Introduction

Permitted uses

The Millimar C 1202 is an electronic length measuring and evaluation instrument for use in production. 

Depending on the N 1700 module used, e.g. two inductive or incremental measuring probes, one or two 

pneumatic measuring instruments can be connected.
The operating, maintenance and repair information detailed in this quick guide and these operating 

instructions must be followed.

To gain maximum benefit from this measuring instrument, you must read the instructions before placing 

it into operation.
The measuring instrument is most accurate after a warm-up period of at least 30 minutes.

The Millimar C 1202 must only be used with the supplied AC adapter. 

The detailed operating instructions can be downloaded at

www.mahr.com/products on the product page.

The scope of delivery of the length measuring instrument includes:

-   Millimar C 1202 measuring instrument

-   AC adapter with interchangeable adaptern

-  Bus termination module

-  Micro SD memory card

-   Quick guide

Содержание Millimar C 1202

Страница 1: ...ompact length measuring instrument 3722972 Millimar C 1202 Quick guide Valid from firmware version 1 0 0 0 Mahr GmbH Carl Mahr Stra e 1 37073 G ttingen Tel 49 551 7073 0 info mahr com www mahr com 102...

Страница 2: ...bol can cause inaccurate results and lead to equipment damage Introduction Permitted uses The Millimar C 1202 is an electronic length measuring and evaluation instrument for use in production Dependin...

Страница 3: ...your company safety officer 4 Before connecting up this measuring instrument please check the local mains supply voltage to ensure that it is within the working range of the AC adaptor 100 V 240 V 50...

Страница 4: ...liability will be accepted for damages caused by other usage or as a result of the incorrect application of this measuring instrument Should your measuring task not be solved with this measuring instr...

Страница 5: ...h dual function 13 1 5 3 Mode display for master measurement 14 1 5 4 Ports 14 2 Initial commissioning applying basic settings 2 1 Switching on 15 2 2 Selecting the display language 15 2 3 Setting the...

Страница 6: ...6 Mahr GmbH Millimar C1202 1 3 2 4 1 Delivery and connections 1 1 Unpacking...

Страница 7: ...7 Mahr GmbH Millimar C1202 microSD B A 5 6...

Страница 8: ...B A 1 2 Scope of delivery Slot for Micro SD memory card Scope of delivery Millimar C 1202 Power supply unit with inter changeable adapter Bus termination module Micro SD memory card Quick guide Bus t...

Страница 9: ...e probes 5331122 Millimar N 1702 U Module for 2 inductive probes 5331125 Millimar N 1702 M HR Module for 2 inductive probes 5331161 Millimar N 1702 Vss Module for 2 incremental probes 5331150 Millimar...

Страница 10: ...sequential Hold down Toggle function Reset max min memory sequential Hold down Toggle function Set zero point parallel Hold down Toggle function Reset max min memory parallel Hold down Toggle function...

Страница 11: ...ion entry Cancel submenu entry Select item Deselect item Save settings to memory card Delete file from memory card Time controlled measuring mode Start measurement Pause measurement Stop measurement R...

Страница 12: ...5 1 Display and operating keys Display Operating keys Scale Master measurement active Warning limit Measured value Tolerance limit Unit Measuring channel active Scale end value Angle in degrees Featu...

Страница 13: ...o functions Pressing the key for longer than two seconds toggles the function Parallel mode Active function Second function Increase scale resolution Reduce scale resolution Hand select feature Start...

Страница 14: ...feature at which the hand is pointing Sequential mode Master measurement is performed for the feature at which the hand is pointing Hand switches automat ically to next feature The master measurement...

Страница 15: ...nstrument and mains socket Press the ON OFF key The following appears on the display Start screen 2 3 Setting the measurement unit Select the relevant measuring unit with or Confirm entry by pressing...

Страница 16: ...uring probe Connect the measuring probe to probe input C1 2 5 Selecting the probe type Press the ON OFF key Menu appears Select Setup 3 with or and Select submenu Probe type C1 with or Select using 4...

Страница 17: ...point before the first measurement To do this use the setup mode that indicates the raw value or absolute value of the probe Select the relevant measuring probe type using or See Technical Data in th...

Страница 18: ...submenu with Confirm entry with 4 key or exit sub menu with key One or two measuring channels will appear Depends on N 1700 module used The value displayed is the direct value from the measuring senso...

Страница 19: ...e set to master value with key Master value 0 2 8 Switching OFF The measuring screen must be ac tive to switch off the C1202 using the ON OFF key Press ON OFF key for at least 2 sec onds The instrumen...

Страница 20: ...20 Mahr GmbH Millimar C1202...