L A D E N M Ü H L E N
S H O P G R I N D E R S
Fault
The grinder does
not start.
7. Operational Problems
Cause
The power supply
plug is not inser-
ted.
The overload
circuit breaker has
been tripped.
The motor pro-
tector has been
triggered.
The pre-fuse was
tripped.
Corrective measure
Insert the plug into the
outlet.
Check to determine whe-
ther the reset button of the
circuit breaker has jumped
out. Press the reset button
in again if appropriate. In
case of repeated tripping of
the circuit breaker, contact
your authorised customer
service centre or dealer.
Give the grinder a break of
approx. 1 hour.
Check the pre-fuse. Restore
the prefuse to its initial sta-
te or replace it. Determine
whether other consuming
grinders are also connected
to this fuse.
Fault
The grinder hums
but does not grind.
Grinder rotates but
without grinding.
Cause
The spout is
clogged.
A foreign object
is in the grinding
mechanism.
Incorrect direction
of rotation.
(correct: counter-
clockwise
Metal parts on the
hopper magnet
obstruct the
incoming fl ow
of material to be
ground.
Corrective measure
Adjust the rotary knob to
„coarse“ and then switch
on the grinder. The grinder
will then grind itself free.
Afterwards, set the rotary
knob back to the desired
grind degree.
Clean the grinding mecha-
nism as described under
9.2 and remove the foreign
object. Observe the safety
instructions!
Have the polarity checked
by an authorized electri-
cian.
Clean the hopper magnet.
In case of other malfunctions or continued faults, please contact your
dealer or your authorised customer service centre.