Page 15
CALIBRATION WEIGHT
TANK
FLUID
USED
LOAD CELLS
NEW
TANK
FLUID
10 kg
CONTAINER
COLLECTION
BLACK HOSE
8 FT.
VALVE
CALIBRATION OF LOAD CELLS
The ATX-2 Plus has two tanks, each mounted on a load cell. One tank is for new fluid and one is for used
fluid. Each tank is
permanently bolted
to a load cell platform which cannot be removed from the unit. The
calibration procedure below must be performed for
both
load cells.
Never calibrate only one load cell as an imbalance may occur and the ATX-2 Plus will not operate
correctly.
1. Remove the rear panel.
2. Place end of
8 ft black hose (left side of ATX-2 Plus)
in bulk used fluid container. Open ball valve on
the end of the hose.
3. Press and hold
4 LITERS
and
20 LITERS
buttons until a long beep is heard.
4. Select which load cell is to be calibrated.
a) Press ----1/2
1/2
1/2
1/2 LITER
LITER
LITER
LITER to calibrate the used fluid load cell.
REMOVE USED FLUID
will be flashing
throughout the remaining steps. A short beep will be heard.
b) Press
+1/2 LITER
to calibrate the new fluid load cell.
ADD NEW FLUID
will be flashing throughout the
remaining steps. A short beep will be heard.
The pump will run and empty the contents of the selected tank through the 8 ft black hose into the
collection container.
5. Press the
STOP
button when fluid is no longer leaving the machine through the black hose and the
selected tank is empty. The pump will stop running. The 4
4
4
4
LITERS
will be flashing. A short beep will be heard. Check that
the tank is empty.
6. Press the
STOP
button again. The
12 LITERS
will be flashing. A
short beep will be heard. This programs the minimum weight.
7. Place two 5 kg or one 10 kg calibration weight on the top of the
selected tank. (10 kg = 22 lbs)
8. Press the
STOP
button. The
12 LITERS
will be illuminated. A
short beep will be heard. This programs the maximum weight.
9. Remove c
alibration weight(s) and replace rear cover.
10
. Press the STOP
button again. A short beep will be heard. The
machine returns to regular operating mode.
Содержание ATX-2 PLUS BOOST
Страница 18: ...Page 17 FLOW WIRING DIAGRAM...