MAINTENANCE
The ATX-2 Plus will provide many years of reliable service if properly maintained. The following checklist will
ensure that the ATX-2 Plus will run at peak efficiency and present an image to your customers that your shop
performs high tech transmission services.
1.
Use tool tray for storage of tools and adapters only.
2.
Keep the exterior surface clean. Use a mild all-purpose cleaner to wipe transmission fluid and dirt off
the cabinet.
3.
Do not allow the unit to sit outside in direct sunlight or inclement weather. Excessive exposure to
sunlight or moisture will cause serious damage and will void the warranty.
4.
The ATX-2 Plus is not intended for mobile use where the unit is transported to customer sites.
Excessive vibration will shorten component life, affect accuracy of performance and void the warranty.
If the ATX-2 Plus needs to be transported by vehicle, remove all fluid, in both the new and used tanks,
prior to transport.
5.
Be gentle when moving the ATX-2 Plus around the shop. Tip the unit and ease the front casters over
any obstacles such as door jams, air hoses and floor irregularities.
6.
Periodically check all internal (by lifting out the tool tray) and external hoses for leaks or excessive
wear. Any weak hoses should be replaced immediately to avoid possible injury.
7.
Check the four filter screens (Item 4 and 6 on Page 15) often to avoid any blockage that may occur.
Clean out debris or replace the filter screen if necessary.
Calibration - A Good Practice
The ATX-2 Plus Boost is the most accurate of all transmission fluid exchange
equipment due to the advanced load cell technology designed into the unit.
Most operating problems are usually fixed by performing a simple calibration
procedure.
A good practice is to periodically calibrate the ATX-2 Plus to ensure optimum
performance.
The following pages describe the reasons for calibration and the actual calibration
procedure.
Precision calibration weight(s) are included with the ATX-2 Plus.