Profi-LON Operation
Eurosystem / Profi-LON
D1 E101BA1-GB09
3.13
3.5.2 Brake
Test
– Single Wheel Test with Remote Control
The single wheel measurement is used for testing the brake effectiveness of only one side. To
turn on roller drive of one vehicle side only use the following keys on the remote control.
Following keys on the remote control are used for this:
Remote Control
IFB3
Motor left
Motor right
b
= Motor off
c
= Motor on
Once test lane is ready (section 3.2.1) proceed as follows:
1 Activate single wheel measurement
Press any Motor-Off key on remote control.
2 Pre-select single wheel test
Press Motor-On key on the remote key to start up desired side of roller set.
3 Conduct brake test
as described in section 3.2.4 “Test procedure with remote control”.
4 Switch off roller set
Roller drive is switched off with Motor-Off key.
Exit assistance device does not work during single wheel test. Switch on both motors
before driving off roller set.
5 Return to standard mode
Press Motor-On keys for both roller sides.