40
BA082901-en
6.5
Checking the Fluid Level
1 Lower lift and wheel-free jack into bottom position.
2 Check the fluid level (see label on power unit).
3 Open the filler neck and top up the reservoir. For specification and fluid quantity
see label on power unit.
4 Also perform a visual check of all hydraulic pipes and hoses.
Replace the hydraulic fluid periodically, depending on aging, soiling and water ab-
sorption.
When topping up, use fluid with the same specification only.
If the lift is operated permanently at an ambient temperature of < 15 °C (59 °F), use
hydraulic fluid with a lower viscosity.
The pressure hoses should be replaced as required, but after six years at the latest.