M A G U I R E P R O D U C T S , I N C .
Edition: August 5, 2014
31
W E I G H S C A L E B L E N D E R
®
Special Instructions for Selected Models
This section relates SPECIAL information about a few selected models.
MICRO PULSE
Micro Pulse valves are available on models:
WSB MB
with optional VERTICAL VALVE MICRO PULSE valves.
WSB 122 / WSB 140m2
with optional SLIDE GATE MICRO PULSE valves.
WSB 131 / WSB 140m1
with optional SLIDE GATE MICRO PULSE valves.
WSB 140Rm1 / WSB 140Rm2
with optional VERTICAL VALVE MICRO PULSE valves.
WSB 240Rm1 / WSB 240Rm2
with optional VERTICAL VALVE MICRO PULSE valves.
WSB 440Rm1 / WSB 440Rm2
with optional VERTICAL VALVE MICRO PULSE valves.
These models may use our "MICRO PULSE" metering system for Color and Additive components.
PULSED OUTPUT parameters control the on/off timing, or pulsing, of the valves. The controlling
parameters are the "PO Pulsed output / timing" component settings.
When set to 00000, normal slide gate operation occurs. When set to a value, such as 00101, power will
pulse ON then OFF, at 1/10 second time intervals each way. This ON/OFF cycling will repeat for the entire
dispense time.
When using a MICRO PULSE valve, you must set the related PO parameter to 00101.
If overall blender throughput is too low, you may increase the metering rate of each Micro Pulse device by
adjusting the cylinder airflow control valves for higher flow rate. This causes more rapid movement of the
cylinder, ejecting more pellets per pulse. The drawback is noisy operation.
We recommend air flow be adjusted for quiet operation, but assuring full valve movement per on/off cycle.
We have already done this. No further adjustment should be necessary.
The approximate correct airflow adjustments are:
At nose of cylinder, 1.5 full turns out from full closed.
At rear of cylinder, 2.5 full turns out from full closed.
MICRO BLENDER slant valves, adjust by sound.
On fixed hoppers with horizontal micro pulse valves, CLEAN OUT of the hopper can be accomplished by
opening the "clean out" port provided under the valve. Turn to one side to allow material to drain.
MICRO PULSE - ACCURACY
All MICRO PULSE valves are more accurate if the associated PT parameter is set to 00090. Read PT
parameter in the PARAMETER section. Use Options / Special Functions / Operating Options /
Progressive Metering, for improved accuracy so long as the additional time necessary for Progressive
Metering exists. Read about more about Progressive Metering in the Controller Functions section.
PROCEED TO:
NORMAL OPERATION
NEXT PAGE
Содержание Weigh Scale Blender WSB
Страница 2: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 2 W E I G H S C A L E B L E N D E R...
Страница 9: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 9 W E I G H S C A L E B L E N D E R...
Страница 13: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 13 W E I G H S C A L E B L E N D E R...
Страница 84: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 84 W E I G H S C A L E B L E N D E R...
Страница 85: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 85 W E I G H S C A L E B L E N D E R...
Страница 86: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 86 W E I G H S C A L E B L E N D E R...
Страница 87: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 87 W E I G H S C A L E B L E N D E R...
Страница 88: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 88 W E I G H S C A L E B L E N D E R...
Страница 89: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 89 W E I G H S C A L E B L E N D E R...
Страница 90: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 90 W E I G H S C A L E B L E N D E R...
Страница 91: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 91 W E I G H S C A L E B L E N D E R...
Страница 92: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 92 W E I G H S C A L E B L E N D E R...
Страница 93: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 93 W E I G H S C A L E B L E N D E R...
Страница 94: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 94 W E I G H S C A L E B L E N D E R...
Страница 95: ...M A G U I R E P R O D U C T S I N C Edition August 5 2014 95 W E I G H S C A L E B L E N D E R...
Страница 96: ...M A G U I R E P R O D U C T S I N C Edition August 6 2014 96 W E I G H S C A L E B L E N D E R...