1.7
About Solution Planning
A smooth deployment of a solution that integrates DynaWave requires some up-front planning and
decision-making:
Determine the overall
functional requirements
and desired
user experience
of the solution
DynaWave will be integrated into.
Determine what
documentation
and
training
will be required from solution design through testing
and field deployment.
Determine what type of
host
DynaWave will connect to, and what
connection type
it will use. The
host can be a computer or specialty board with a USB port or UART port (for example, MagTek’s
mDynamo EMV Contact Reader / Transaction Hub Module). When planning, include any additional
support or devices required by the host and its connection, such as physical locations, mounting, and
power connections.
provides a list of available compatible devices and accessories.
Determine what
software
will be installed on the host and how it will be configured. Software can
include operating system, transaction processing software, security software, board firmware, and so
on. Include any additional support required by the software, such as network connections.
Determine how DynaWave should be
configured
, and specify that when you order devices. MagTek
or your reseller can advise. For deep detail about configuration options and how they affect device
behavior, see
D998200215 DYNAWAVE PROGRAMMER'S MANUAL (COMMANDS)
.
Determine how the solution design will integrate DynaWave electrically (see section
Determine how the solution design will integrate DynaWave mechanically (see section
Develop an
installation procedure
. Basic device installation steps are provided in section
, but installing technicians will need solution-specific materials. If DynaWave will be
incorporated into a solution before shipping, the installation procedure would be an assembly drawing
or assembly and test work instructions.
Determine how the solution will be
tested
and, if appropriate, how it will be
certified
.
Determine how the solution will be
maintained
. See section
maintaining the DynaWave portion of the solution.
Determine how the solution will be
regularly inspected
. Proper inspection requires additional
solution-specific training, instructions, and visual references for inspecting the entire solution for
tampering, unauthorized added components such as eavesdropping or skimming devices, and so on.
Table 1-1 - Available Accessories
Part Number
Description
Related Sections
21079812
MDYNAMO
1000003798
CABLE, UART, DYNAWAVE
1000004824
ESD HARNESS CABLE, DYNAWAVE
Grounding / ESD Protection
UART Port [J6]
1000002547
CABLE, USB A PLUG TO RIGHT ANGLE
MICRO USB B PLUG