2 - Electrical Integration
DynaWave| OEM Contactless NFC Module | Installation and Operation Manual
Page 17 of 39 (
D998200265-10
)
2.4
Shielding and Conditioning
MagTek recommends using shielded cables to provide noise immunity and to prevent radiated emissions.
The device itself has been tested by an FCC lab for Class B radiated emissions and susceptibility, and has
no special shielding requirements. For details, see the FCC information provided at the beginning of this
document.
MagTek also recommends that all communication cabling should be draped together where possible, and
isolated from the earth grounding cable to DynaWave and any other unrelated wiring at the installation
site that could potentially couple noise into the device.
The device has no special requirements for power conditioning or signal conditioning.