MAGSWITCH
CoBot SmartMagGrip E30 URCap Manual
+ 1(303) 468.0662
magswitch.com
1101607 r02
For more information, contact our Application Engineers at +1.303.486.0662 or magswitch.com/information-request
Page 25
5.
Unit positioned with North Pole outside of Calibrated Part Present signal range and the magnet is electrically actuated on
(100%), by setting Requested Position = 100 (Magnet 100% ON) or issuing Turn Magswitch Full On command:
a.
Magswitch Full On indication LED Turns On
b.
Check below table for the expected LED Indication values at this step
LED Indication
Value
Input Word 2: Bit 9 (S Pole On)
On
Input Word 2: Bit 8 (N Pole On)
Off
Part Present
Off
6.
Unit position with neither pole within the Calibrated Part Present signal range and the magnet is electrically actuated on (100%),
by setting Requested Position = 100 (Magnet 100% ON) or issuing Turn Magswitch Full On command:
a.
Magswitch Full On indication LED Turns On
b.
Check below table for the expected LED Indication values at this step
Bit Number (Short Name)
Bit Return Value
S Pole On
Off
N Pole On
Off
Part Present
Off