PROPORTIONAL GAIN (33)
Generates an output adjustment proportional to the error.
START TIME (22)
Provides a soft-start when starting with a slack web. The output is
limited to the HOLD LEVEL at start, but the limit level is increased with
time. This is the time taken to increase the limit to full output. A longer
start time will provide a softer start.
STOP MULTIPLIER (24)
Upon receipt of a stop signal, the output is increased by this multiplier
(1 creates no increase). Since the output is proportional to roll
diameter, this is a simple adjustment for roll inertia.
STOP TIME (23)
This is the time that DIGITRAC 2 stays in STOPPING (automatic)
mode after the stop signal is received. At the end of this time the
control goes to HOLD mode. Stop time should be slightly longer than
actual machine stopping time.
PROGRAM-CONFIGURE SCREENS
DIAMETER INPUT TYPE (11)
NONE, VOLTAGE, or PULSE.
IS INERTIA COMP USED
YES, NO
IS TAPER TENSION USED
YES, NO
HOLD LEVEL CHANGES
WITH DIAMETER
YES, NO
HOLD LEVEL CHANGES
WITH TENSION
YES, NO
OUTPUT RANGE
Normal, -10 vdc to +10 vdc
OPTIMIZE METHOD (44)
PI or PID.
SELECT LANGUAGE
ENGLISH, FRANCAIS, DEUTSCH, ESPANOL, or ITALIANO
SELECT UNITS (42)
(lb, in), (kgm, mm), (n, mm)
SPEED INPUT TYPE (47)
NONE, VOLTAGE, or PULSE.
TENSION ON/OFF
TOGGLE, LEVEL.
The following appear only if taper tension is used:
CORE DIAMETER (14)
CORE TENSION is commanded at this diameter.
FULL ROLL DIA. (12)
At this diameter the tension will be reduced by the taper percent.
11