Floor temperature limiter:
Some floor coverings must be limited at a certain maximum temperature (for example wooden floors).
When the option ‘Wooden’ is selected (in the start up wizard), the floor will not exceed 28ºC.
When using this option a floor sensor needs to be installed. In case of doubt please check with the
supplier of your floor covering if there are limits for maximum temperature.
Electrical Installation manual:
3.1 Attention:
Before installation or re-installation of the thermostat always isolate the power to the thermostat.
Installation needs to be done by a qualified electrician in accordance with all current wiring and
building regulations. The MAGNUM Intelligent Control thermostat is provided with an intelligent help-
function which guides the user through the program and is very user friendly.
3.2 Installer instructions:
Check if the power is off. Remove the display frame by pushing a non sharp instrument (for example
the point of a ballpoint pen) carefully in the square whole underneath the thermostat.
The display frame and the cover frame can be removed. Position the thermostat and install onto the
back box (not supplied). Place the display frame back into position by pushing it softly.
Attention: When the power is put on for the first time it takes 5 minutes before the first
question of the start up menu (Ref 1.1) appears. Follow the start-up menu carefully.
3.3 Connection schedule:
Connection as followed:
-
Terminal 1 and 4 are for the connecting heating cables.
-
Terminal 2 (Neutral) & 3 (Live) are used for power connection.
-
Terminal 7 & 8 are for the sensor connections
-
Terminal 6 is used for connecting the earth of the heating cable and the earth from the power
supply. Anyhow we advice to make an external connection from the thermostat.
Image 1: earth connection not through the thermostat.
Image 2: earth connection through the thermostat.
3.4 Technical data:
Voltage
:230V – 50/60 Hz
Max. load
:max. 16 Amp. / 230V
Temperature range:
: + 5/ +40 degree Celsius
Cover:
: IP 21,
Standard colour
: Polar white(RAL 9010)
Guarantee:
: 2 years manufacturer warranty .
Approvals:
: FI /CE/CCA