Sensor may be wired incorrectly or loosely. Heating system will not work when there is a sensor fault. 
The red LED will flash. 
Advice: Check the wiring of the floor sensor and tighten terminals. If the connection is sound and the 
sensor error is still shown we advice you to contact our helpdesk (Ref 4). 
Temperature on display: 
The temperature shown on the main screen is the current measured temperature (it is not you’re 
installed comfort temperature).  
 
 

Intelligent function: 

The thermostat has a self thinking and adaptive system. This function enables the thermostat to 
calculate when it needs to switch on so that the required temperature is reached at the set time. (i.e. if 
the set time is 08.00, the thermostat will switch on earlier so that the set temperature is reached at 
08.00). This intelligent function can be turned off in the menu: 

Other functions.

 

 
 
 
 
 

The standard automatic program settings are: 

Comfort heating from Monday till Sunday from 06.00 till 09.00 and from 15.00 till 22.00. Outside these 
hours the thermostat switches to setback mode. 
 
 

Setback mode: 

The setback mode is when the thermostat 

‘sets back’

 to a lower temperature during the off time 

periods. This is the most economical and efficient way to achieve the best energy consumption. This 
function is part off the self thinking adaptive system 
 
 

Heating new floors: 

Allow the floor sufficient drying time before you turn on the floor heating. For tiled floors a drying time 
of 3-4 weeks after installation should generally be observed. Consult the supplier/manufacturer 
regarding the applicable drying time for the product. For sand/cement screed floors a drying time of 1 
week per applied cm with a minimum of 4-5 weeks is generally observed. 
 
 

Energy consumption: 

The energy consumption depends on a lot factors. The important factors are: individual preference 
(which temperature you feel is comfortable), insulation, settings of the thermostat, humidity in the 
room, separate rooms, location, etc.  In the chapter “energy and consumption” on our website, you will 
find more specified information. The thermostat registers the energy consumptions and can be easily 
be read in the screen “energy consumption”. You will see the percentile energy consumption over the 
last 30 and 365 days. 

 

How to calculate your energy consumption:  
30 days: 24 hours x 30 days x total installed power (kW) x % = energy consumption  
365 days: 24 hours x 365 days x total installed power x % = energy consumption 
 
Example: 
The thermostat gives a percentage of 26% over 30days. 
The power installed in the floor is 700 Watt 
24 hours x 30 days = 720 hours. 
720 hours x 0.7 kW = 504 kWh 
26% of 504 kWh = 131 kWh. 
 
The heating system has used 131 kWh the last 30 days. 
 
 
 

Back-up battery: 

The thermostat has a back-up battery. When the power of the thermostat is switched off (for example 
a power cut), the time and date will be maintained when power is regained. The other settings are 
saved in the memory of the thermostat 
 

Содержание Intelligent Control

Страница 1: ...LED colours signals Explanation of text symbols in main screen Intelligent function Standard automatic program Setback mode Heating new floors Energy consumption Back up battery Floor temperature limi...

Страница 2: ...you can press the symbol X left key and go back to the former screen or option 1 Language make your language choice This is the first question in the start up menu 2 Preference choice clock choose 12...

Страница 3: ...can be the standard settings or the custom time settings 3 Manual control To permanently override the automatic program To cancel the manual mode choose the automatic mode 4 Off Turns the thermostat a...

Страница 4: ...en switched on allowing you to monitor your energy consumption The total switched on time is by percentage shown over the last 30 and 365 days Ref 2 8 4 Child lock The thermostat is locked with this f...

Страница 5: ...his can be a central source or a smart home system This function can be turned on or off Sensor type gives the possibility to adjust the sensor value This is not required in a standard situation Consu...

Страница 6: ...rying time before you turn on the floor heating For tiled floors a drying time of 3 4 weeks after installation should generally be observed Consult the supplier manufacturer regarding the applicable d...

Страница 7: ...frame and the cover frame can be removed Position the thermostat and install onto the back box not supplied Place the display frame back into position by pushing it softly Attention When the power is...

Страница 8: ...C F Technieken 2007 No rights can be...

Отзывы: