![Magnum Intelligent Control Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/magnum/intelligent-control/intelligent-control_user-manual_3609779005.webp)
-Temperature: Choose Celsius or Fahrenheit
7. Other functions:
Adjustments and corrections can be done from this menu.
Attention: Adjustments can have a big
influence on the working of the thermostat! Please consult your supplier.
The following options are:
Heating system:
-
Type of heating system
-
Installation depth of the system (floor heating)
-
Floor covering: wood or other
-
Temperature
These settings can be changed using the start up wizard.
-
Calibration; a correction can be made here on the sensor temperature in the display and the
measured floor or room temperature. Consult your supplier before changing calibration setting.
-
Intelligence; Switch the intelligent function on or off.(Default is ON)
See Ref 2.3
-
Differential: the difference between switch on and off period during heating time.
Consult your supplier before changing differential settings.
-
Pilot function: Can be used to operate the thermostat through an external source. This can be a
central source or a smart home system. This function can be turned on or off.
-
Sensor type; gives the possibility to adjust the sensor value. This is not required in a standard
situation. Consult your supplier before changing sensor type.
-
Start up wizard; starts the configuration wizard.
-
Reset; all settings are restored to the factory default settings. To confirm hold the right button for 5
seconds to activate the reset. The thermostat reverts back to the start up wizard.
2. General information:
Explanation of LED colours / signals:
Red: power consumption
Green: system operational
Red light flashing on and off: Sensor fault. (Ref 2.2)
Explanation of text / Symbols in the main screen:
-
Comfort period
-
Limited floor temperature achieved (28 ºC)
-
Child lock activated
-
Electrical use for heating
-
Following symbols only in combination with an active Pilot function:
-
Set back: standard set back temperature (pilot wire)
-
Set back: anti frost + 7 degree Celsius( pilot wire)
-
Set back: thermostat off (pilot wire)
-
Set back: effective temperature -1 degree Celsius (pilot wire)
-
Set back: effective temperature -2 degree Celsius(pilot wire)
Sensor error / fault:
Содержание Intelligent Control
Страница 8: ...C F Technieken 2007 No rights can be...