background image

w

w

w

.m

ag

ne

tro

l.c

om

BENELUX 

Heikensstraat 6, 9240 Zele, België -Belgique

FRANCE 

Tel. +32 (0)52.45.11.11  •  Fax. +32 (0)52.45.09.93  •  E-Mail: [email protected]

DEUTSCHLAND 

Alte Ziegelei 2-4, D-51491 Overath

 

Tel. +49 (0)2204 / 9536-0  •  Fax. +49 (0)2204 / 9536-53  •  E-Mail: [email protected]

INDIA 

B-506, Sagar Tech Plaza, Saki Naka Junction, Andheri (E), Mumbai - 400072

 

Tel. +91 22 2850 7903  •  Fax. +91 22 2850 7904  •  E-Mail: [email protected]

ITALIA 

Via Arese 12, I-20159 Milano

 

Tel. +39 02 607.22.98  •  Fax. +39 02 668.66.52  •  E-Mail: [email protected]

RUSSIA 

198095 Saint-Petersburg, Marshala Govorova street, house 35A, office 427

 

Tel. +7 812 320 70 87  •  E-Mail: [email protected]

U.A.E. 

DAFZA Office 5EA 722 • PO Box 293671 • Dubai

 

Tel. +971-4-6091735  •  Fax +971-4-6091736  •  E-Mail: [email protected]

UNITED 

Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL

KINGDOM 

Tel. +44 (0)1444 871313  •  Fax +44 (0)1444 871317  •  E-Mail: [email protected]

BULLETIN N°:

BE 50-660.2

EFFECTIVE:

JANUARY 2016

SUPERSEDES:

April 2002

UNDER RESERVE OF MODIFICATIONS

IMPORTANT

SERVICE POLICY

Owners  of  Magnetrol  products  may  request  the  return  of  a  control;  or,  any  part  of  a  control  for  complete  rebuilding  or 

replacement. They will be rebuilt or replaced promptly. Magnetrol International will repair or replace the control, at no cost to

the purchaser, (or owner) other than transportation cost if:

a. Returned within the warranty period; and,

b. The factory inspection finds the cause of the malfunction to be defective material or workmanship.

If the trouble is the result of conditions beyond our control; or, is NOT covered by the warranty, there will be charges for labour

and the parts required to rebuild or replace the equipment.

In some cases, it may be expedient to ship replacement parts; or, in extreme cases a complete new control, to replace the

original  equipment  before  it  is  returned. If  this  is  desired,  notify  the  factory  of  both  the  model  and  serial  numbers  of  the 

control to be replaced. In such cases, credit for the materials returned, will be determined on the basis of the applicability of

our warranty.

No claims for misapplication, labour, direct or consequential damage will be allowed.

RETURNED MATERIAL PROCEDURE

So that we may efficiently process any materials that are returned, it is essential that a “Return Material Authorisation” (RMA)

form will be obtained from the factory. It is mandatory that this form will be attached to each material returned. This form is

available through Magnetrol’s local representative or by contacting the factory. Please supply the following information:

1. Purchaser Name

2. Description of Material

3. Serial Number and Ref Number

4. Desired Action

5. Reason for Return

6. Process details

Any unit that was used in a process must be properly cleaned in accordance with the proper health and safety standards

applicable by the owner, before it is returned to the factory.

A material Safety Data Sheet (MSDS) must be attached at the outside of the transport crate or box.

All shipments returned to the factory must be by prepaid transportation. Magnetrol will not accept collect shipments.

All replacements will be shipped Ex Works.

Содержание Kotron 805 series

Страница 1: ...R F Capacitance Level Transmitter Installation and Operating Manual Kotron 805...

Страница 2: ...wire is xed to the PCB by means of a spade plug Disconnect white probe wire always at the probe never at the electronics see above For installation details see bulletin BE50 125 Bent probe Flexible pr...

Страница 3: ...d local current meter Ex Non Ex Ex Non Ex Ex Non Ex CAUTION ALWAYS check for proper grounding Improper grounding will cause malfunction of the unit CALIBRATION NOTE When connected to an approved barri...

Страница 4: ...is the highest level from which the calibration is performed Hi Cal is measured from the end of the probe Lo Cal cm or inches Low Calibration point is the lowest level from which the calibration is p...

Страница 5: ...r a single transmitter installation Fine tune the 4 mA point Attach a mA meter to the output If the output does not equal 4 0 mA adjust the value on the display to equal 4 00 mA Fine tune the 20 mA po...

Страница 6: ...Room Display Power Supply Current Meter 250 RL 450 CONNECTIONS Connection of your Hart communicator at power terminals and in wiring compartment at rst junction box between unit and control room HART...

Страница 7: ...HART software does not Contact manufacturer of your HART information e g Mfgs ID Device account for Mfgs ID s greater master software for upgrade This is a Serial etc but will not read any than 63 Mag...

Страница 8: ...Expedite Ship Plan ESP Parts covered by ESP service are conveniently grey coded in the selection tables 1 Electronic module Digit 5 Digit 6 Replacement part 0 1 031 2809 003 2 031 2809 023 3 031 2809...

Страница 9: ...Electronic Module Yes Yes Yes Yes Yes Yes Yes No No No No No No Display has Text No Reseat Boards Check Power Supply and Wiring Loop Resistance Wrong Correct Loop Resistance Start Good Display No Act...

Страница 10: ...lure to Operate with Correct Loop Inputs Display Working Yes No Retest Unit Good Display Key Board Responds Replace Electronic Module No Check Loop Current at Wiring Board Loop Current 22 4 0 mA Adjus...

Страница 11: ...heck Calibration Parameters Yes Yes Yes Corrupt Display Text Replace Electronic Module No Yes Replace Electronic Module Same Error Message Retest No Yes Active HART Analog Loop Correct Trim 4 20mA Che...

Страница 12: ...ish French or German Housing Material Aluminium A356T6 0 25 copper or 316 SST 1 4401 IP 66 Net and Gross Weight 2 70 kg net 3 20 kg gross Overall Dimensions H 214 mm 8 43 x W 111 mm 4 38 x D 188 mm 7...

Страница 13: ...ide view Optional Mounting Flange 3 4 NPT 1 NPT 1G 1 BSP Optional Mounting Flange Optional Anchor Assembly Optional Weight 13 0 50 bare probe 16 0 625 insulated probe 5 0 1875 6 0 2500 75 2 95 34 1 32...

Страница 14: ...T6 A complete measuring system consists of 1 Kotron 805 transmitter head electronics 2 KOTRON Probe a full range of rigid and exible probes for conductive and non conductive media is available see bu...

Страница 15: ...15 Notes...

Страница 16: ...tive material or workmanship If the trouble is the result of conditions beyond our control or is NOT covered by the warranty there will be charges for labour and the parts required to rebuild or repla...