background image

IMPORTANT

SERVICE POLICY

Owners  of  Magnetrol  products  may  request  the  return  of  a  control;  or,  any  part  of  a  control  for  complete  rebuilding  or 

replacement. They will be rebuilt or replaced promptly. Magnetrol International will repair or replace the control, at no cost to

the purchaser, (or owner) 

other than transportation cost 

if:

a. Returned within the warranty period; and,

b. The factory inspection finds the cause of the malfunction to be defective material or workmanship.

If the trouble is the result of conditions beyond our control; or, is 

NOT 

covered by the warranty, there will be charges for labour

and the parts required to rebuild or replace the equipment.

In some cases, it may be expedient to ship replacement parts; or, in extreme cases a complete new control, to replace the

original  equipment  before  it  is  returned. If  this  is  desired,  notify  the  factory  of  both  the  model  and  serial  numbers  of  the 

control to be replaced. In such cases, credit for the materials returned, will be determined on the basis of the applicability of

our warranty.

no claims for misapplication, labour, direct or consequential damage will be allowed.

RETURNED MATERIAL PROCEDURE

So that we may efficiently process any materials that are returned, it is essential that a “Return Material Authorisation” (RMA)

form will be obtained from the factory. It is mandatory that this form will be attached to each material returned. This form is

available through Magnetrol’s local representative or by contacting the factory. Please supply the following information:

1. Purchaser name

2. Description of Material

3. Serial number

4. Desired Action

5. Reason for Return

6. Process details

All shipments returned to the factory must be by prepaid transportation. Magnetrol 

will 

not

accept 

collect shipments.

All replacements will be shipped FOB factory.

w

w

w

.m

ag

ne

tro

l.c

om

BENELUX 

Heikensstraat 6, 9240 Zele, België -Belgique

FRANCE 

Tel. +32 (0)52.45.11.11  •  Fax. +32 (0)52.45.09.93  •  E-Mail: [email protected]

DEUTSCHLAND 

Alte Ziegelei 2-4, D-51491 Overath

 

Tel. +49 (0)2204 / 9536-0  •  Fax. +49 (0)2204 / 9536-53  •  E-Mail: [email protected]

INDIA 

B-506, Sagar Tech Plaza, Saki Naka Junction, Andheri (E), Mumbai - 400072

 

Tel. +91 22 2850 7903  •  Fax. +91 22 2850 7904  •  E-Mail: [email protected]

ITALIA 

Via Arese 12, I-20159 Milano

 

Tel. +39 02 607.22.98  •  Fax. +39 02 668.66.52  •  E-Mail: [email protected]

RUSSIA 

Business center “Farvater”, Ruzovskaya Street 8B, office 400A, 190013 St. Petersburg

 

Tel. +7 812 320 70 87  •  E-Mail: [email protected]

U.A.E. 

DAFZA Office 5EA 722 • PO Box 293671 • Dubai

 

Tel. +971-4-6091735  •  Fax +971-4-6091736  •  E-Mail: [email protected]

UNITED 

Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL

KINGDOM 

Tel. +44 (0)1444 871313  •  Fax +44 (0)1444 871317  •  E-Mail: [email protected]

BUllETIn n°:

BE 47-602.16

EFFECTIVE:

DECEMBER 2014

SUPERSEDES:

May 2003

UnDER RESERVE OF MODIFICATIOnS

Содержание F10

Страница 1: ...magnet and switch assembly to return to the no Flow position Switch mechanism Adjusting screw Magnetic sleeve Actuating vane Magnet NO FLOW POSITION POSITION WITH ACTUATING FLOW PRESENT AGENCY APPROVA...

Страница 2: ...for trimming vane to correct length Remove 2 arrows not parallel with pipe 8 Remove F10 from pipeline 9 Check position of arrow stamped on vane support bracket This arrow should be pointing parallel w...

Страница 3: ...res conductors wrap them around enclosing tube beneath the baf e plate and connect to proper terminals Check to be certain that excess wire does not interfere with tilt of switch and that adequate cle...

Страница 4: ...AB BK9 BC9 BK5 BU5 BKB 1 x DPDT B8B BDB Bn9 BF9 BD5 BW5 BnB C 1 x SPDT C2B CAB CK9 CC9 C2T CAT CK5 CU5 CKB 1 x DPDT C8B CDB Cn9 CF9 C8T CDT CD5 CW5 CnB D 1 x SPDT D2B DAB DK9 DC9 DK5 DU5 DKB 1 x DPDT...

Страница 5: ...nEMA 4X 108 151 257 48 4 29 5 93 10 12 1 88 nEMA 7 9 100 143 246 42 3 94 5 63 9 68 1 65 CEnElEC 110 143 249 45 4 33 5 63 9 80 1 77 Pneum sw J 110 118 216 39 4 33 4 64 8 50 1 53 Pneum sw K 130 118 216...

Страница 6: ...0 Safety retainer 1 89 5912 001 89 5913 001 189 5914 001 189 5928 001 89 5929 001 189 5930 001 11 Washer 1 12 O ring 1 13 Adjustment screw 1 14 Enclosing tube 1 15 Enclosing tube gasket 1 12 1204 001...

Страница 7: ...7 REPLACEMENT PARTS cont Threaded mounting Flanged mounting Serial number tage ref...

Страница 8: ...actory It is mandatory that this form will be attached to each material returned This form is available through Magnetrol s local representative or by contacting the factory Please supply the followin...