background image

BULLETIN:  57-657.0
EFFECTIVE:  June 2016

705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000 • Fax 630-969-9489
[email protected] • www.magnetrol.com

Copyright © 2016 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.

ASSURED QUALITY & SERVICE COST LESS

ECLIPSE Guided Wave Radar transmitters may be protected by one or more of the following U.S. Patent Nos.
US 6,626,038; US 6,640,629; US 6,642,807; US 6867729; US 6879282; US 6906662. Other patents pending.

Disclaimer

The SIL values in this document are based on an FMEDA analysis using exida’s SILVER Tool. MAGNETROL
accepts no liability whatsoever for the use of these numbers or for the correctness of the standards on which the
general calculation methods are based.

Magnetrol, Magnetrol logotype and Eclipse are registered trademarks of Magnetrol International, Incorporated.
F

OUNDATION

fieldbus logo is a registered trademark of the Fieldbus Foundation.

HART is a registered trademark of the HART Communication Foundation.
PACTware is trademark of PACTware Consortium.

References

• IEC 61508 Edition 2.0,2010

“Functional Safety of Electrical/Electronic/
Programmable Electronic Safety Related Systems”

• ANSI/ISA-84.00.01-2004 Part 1 (IEC 61511-1Mod)

“Functional Safety: Safety Instrumented Systems for
the Process Industry Sector – Part 1 Hardware and
Software Requirements”

• ANSI/ISA-84.00.01-2004 Part 2 (IEC 61511-2Mod)

“Functional Safety: Safety Instrumented Systems for
the Process Industry Sector – Part 2 Guidelines for 

the Application of ANSI/ISA84.00.01-2004 Part 1
(IEC 61511-1 Mod) – Informative”

• ANSI/ISA-84.00.01-2004 Part 3 (IEC 61511-3Mod)

“Functional Safety: Safety Instrumented Systems for
the Process Industry Sector – Part 3 Guidance for the
Determination of the Required Safety Integrity Levels
– Informative”

• ANSI/ISA-TR84.00.04 Part 1 (IEC 61511 Mod)

“Guideline on the Implementation of ANSI/ISA-
84.00.01-2004”

Service Policy

Owners  of  MAGNETROL  controls  may  request  the
return of a control or any part of a control for complete
rebuilding or replacement. They will be rebuilt or replaced
promptly. Controls returned under our service policy must
be  returned  by  prepaid  transportation.  MAGNETROL
will  repair  or  replace  the  control  at  no  cost  to  the  pur-
chaser (or owner) other than transportation if:

1.  Returned within the warranty period; and
2.  The factory inspection finds the cause of the claim to

be covered under the warranty.

If the trouble is the result of conditions beyond our con-
trol;  or,  is  NOT  covered  by  the  warranty,  there  will  be
charges  for  labor  and  the  parts  required  to  rebuild  or
replace the equipment.

In  some  cases  it  may  be  expedient  to  ship  replacement
parts;  or,  in  extreme  cases  a  complete  new  control,  to
replace  the  original  equipment  before  it  is  returned.  If
this is desired, notify the factory of both the model and
serial  numbers  of  the  control  to  be  replaced.  In  such
cases, credit for the materials returned will be determined
on the basis of the applicability of our warranty.

No claims for misapplication, labor, direct or consequen-
tial damage will be allowed.

Return Material Procedure

So  that  we  may  efficiently  process  any  materials  that  are
returned,  it  is  essential  that  a  “Return  Material
Authorization”  (RMA)  number  be  obtained  from  the
factory  prior  to  the  material’s  return.  This  is  available
through a MAGNETROL local representative or by con-
tacting the factory. Please supply the following information:

1.  Company Name
2.  Description of Material
3.  Serial Number
4.  Reason for Return
5.  Application

Any  unit  that  was  used  in  a  process  must  be  properly
cleaned in accordance with OSHA standards, before it is
returned to the factory.

A Material Safety Data Sheet (MSDS) must accompany
material that was used in any media.

All shipments returned to the factory must be by prepaid
transportation.

All replacements will be shipped F.O.B. factory.

Содержание ECLIPSE 706 Series

Страница 1: ...n the output will be driven to the customer specified out of range signal i e 3 6 mA or 21 mA The Enhanced Model 706 is certified for use in low demand level measurement applications Application The H...

Страница 2: ...ronmental 6 6 1 2 1 Operating 6 6 1 2 2 Storage 6 6 2 Installation 6 6 3 Skill Level of Personnel 6 6 4 Necessary Tools 7 6 5 Configuration Information 7 6 5 1 General 7 6 5 2 Configuration 7 6 5 3 Wr...

Страница 3: ...the liquid level The amplitude of the reflection depends on the dielectric con stant of the product The higher the dielectric constant the larger the reflection 1 3 Determining Safety Integrity Level...

Страница 4: ...Serial Number shown on the name plates 3 0 Level Measuring System The diagram at left shows the structure of a typical measuring system incorporating the ECLIPSE Model 706 transmitter This SIL 2 3 Ce...

Страница 5: ...an Time To Repair MTTR SIL determinations are based on a number of factors including the Mean Time To Repair MTTR The analysis for the ECLIPSE Model 706 is based on a MTTR of 24 hours 5 0 Supplementar...

Страница 6: ...Manual 57 606 for Environmental limitations 6 1 2 1 Operating The operating temperature range is 40 to 175 F 40 to 80 C 6 1 2 2 Storage The device should be stored in its original shipping box and not...

Страница 7: ...nfiguration Ensure the Model 706 transmitter has been properly config ured for the application and probe Special consideration should be given to the following configuration parameters Dielectric Rang...

Страница 8: ...nse Times Continuous internal diagnostics are present within the Enhanced ECLIPSE Model 706 transmitter In the event a Fault is detected a message will appear on the LCD and the output current will be...

Страница 9: ...indicate OK b Choose the menu DIAGNOSTICS EVENT HISTORY Event Log i Any FAULT or WARNING messages must be investigated and understood ii Corrective actions should be taken for FAULT messages continued...

Страница 10: ...curves a Select DIAGNOSTICS ECHO CURVE View Echo Curve i Observe the present Echo Curve identify the characteristic portions of the waveform related to the FIDUCIAL Process level End of Probe and othe...

Страница 11: ...figuration parameters avail able via the Local User Interface during normal operation The end user will enable the User Password to lock out any end user modifiable configuration parameters avail able...

Страница 12: ...will respond to a change from the user s process within the safety function response time The Eclipse Model 706 shall transition to the Faulted Mode from the Normal Mode within the Diagnostic Test Int...

Страница 13: ...13 57 657 SIL Certified Safety Manual for ECLIPSE Model 706 9 0 Appendices 9 1 SIL Certificate...

Страница 14: ...14 57 657 SIL Certified Safety Manual for ECLIPSE Model 706 9 2 FMEDA Report exida Management Summary...

Страница 15: ...itself and its operating conditions The assumption of a constant failure rate is based on the bathtub curve Therefore it is obvious that the PFDavg calculation is only valid for components that have...

Страница 16: ...Mod Guideline on the Implementation of ANSI ISA 84 00 01 2004 Service Policy Owners of MAGNETROL controls may request the return of a control or any part of a control for complete rebuilding or replac...

Отзывы: