33
48-635 E3 Modulevel
®
Displacer Level Transmitter
Transmitter Codes
Agency
Model
Digits 8, 9 and 10
Approval/Standards
ATEX
EXX-XXXX
x1E, x1F, x1G, x1H
Flameproof
x2E, x2F, x2G, x2H
ATEX Ex II 1/2 G Ex d IIC T6
x3E, x3F, x3G, x3H
EN 60079-0, EN 60079-1,
x4E, x4F, x4G, x4H
EN 60079-26
x5E, x5F, x5G, x5H
94/9/EC
x6E, x6F, x6G, x6H
x8E, x8F, x8G, x8H
EXX-XXXX
x1A, x1B, x1C, x1D
Intrinsically Safe
¡
x2A, x2B, x2C, x2D
ATEX Ex II 1 G Ex ia IIC T4
x3A, x3B, x3C, x3D
EN 60079-0, EN 60079-11,
x4A, x4B, x4C, x4D
EN 60079-26, EN 60079-27
x5A, x5B, x5C, x5D
94/9/EC
x6A, x6B, x6C, x6D
x8A, x8B, x8C, x8D
EXX-XXXX
x1A, x1B, x1C, x1D
Non-Sparking
x2A, x2B, x2C, x2D
ATEX Ex II 3 G Ex ic II T6
x3A, x3B, x3C, x3D
EN 60079-0
x4A, x4B, x4C, x4D
EN 60079-11
x5A, x5B, x5C, x5D
94/9/EC
x6A, x6B, x6C, x6D
x8A, x8B, x8C, x8D
IEC
EXX-XXXX
x1E, x1F, x1G, x1H
Flameproof
x2E, x2F, x2G, x2H
IECEx Ex d IIC T6 Ga/Gb
x3E, x3F, x3G, x3H
IEC 60079-0
IEC 60079-1
IEC 60079-26
EXX-XXXX
x1A, x1B, x1C, x1D
Intrinsically Safe
¡
x2A, x2B, x2C, x2D
IECEx Ex ia IIC T4 Ga
x3A, x3B, x3C, x3D
IEC 60079-0
IEC 60079-11
IEC 60079-26
IEC 60079-27
These units have been tested to
EN 61326 and are in compliance with
the EMC Directive 2004/108/EC.
¿
On remote electronics housing only, seal is required within 18 inches.
¡
Entity parameters for intrinsically safe installation:
FM/CSA
V
max
= 28.6 V
P
max
= 1 W
L
i
= 9.4 µH
I
max
= 140 mA
C
i
= 5.5 nF
ATEX
V
max
= 28.4 V
P
max
= 0.67 W
L
i
= 3 µH
I
max
= 94 mA
C