28
46-649 Jupiter Magnetostrictive Transmitter - F
OUNDATION
fieldbus™
5.5
Model Numbers
5.5.1 Enhanced Jupiter Magnetostrictive Transmitter
2
Enhanced Jupiter Magnetostrictive
TRANSMITTER TYPE
See page 29
MOUNTING CONNECTION
See page 29
FLOAT
See page 30
INSERTION LENGTH
4
LCD display, 4–20 mA & HART, SIL 1
5
LCD display & F
OUNDATION
Fieldbus
™
6
LCD display, 4–20 mA & HART, SIL 2
7
Interface transmitter, 4–20 mA & HART, with LCD display, 2 floats
8
Interface transmitter, F
OUNDATION
Fieldbus, with LCD display, 2 floats
OUTPUT
D
Direct Insertion, Construction codes 1 through 7
E
Top Mount, Construction code 1
F
Top Mount Offset, Construction code 1
G
Top Mount Offset, high-temperature bend, Construction code 7
H
Bottom Mount Offset, Construction code 1
J
Bottom Mount Offset, high-temperature bend, Construction code 7
CONFIGURATION (see drawings on page 34)
E
Inches
M
Centimeters
PROBE UNITS
1
316/316L SS (standard), +250° F (+120° C) Maximum (Direct Ins200° F (+95°))
7
316/316L SS (high temperature) +500° F (+260° C) Maximum
2
Hastelloy
®
C, +200° F (+95° C) Maximum
3
Monel
®
, +200° F (+95° C) Maximum
5
Electropolished 316/316L SS, +200° F (+95° C) Maximum
6
Sanitary 316/316L SS, +200° F (+95° C) Maximum
MATERIALS OF CONSTRUCTION
1
Cast Aluminum, Integral Mount with
3
⁄
4
" NPT Conduit Entry
FM, EP, NI & IS
2
Cast Aluminum, Integral Mount with M20 Conduit Entry
FM, EP, NI & IS
3
316 SS, Integral Mount with
3
⁄
4
" NPT Conduit Entry
FM, EP, NI & IS
4
316 SS, Integral Mount with M20 Conduit Entry
FM, EP, NI & IS
A
Cast aluminum, Integral Mount with
3
⁄
4
" NPT conduit entry
ATEX, EEx d
B
Cast aluminum, Integral Mount with M20 conduit entry
ATEX, EEx d
C
316 SS, Integral Mount with
3
⁄
4
" NPT conduit entry
ATEX, EEx d
D
316 SS, Integral Mount with M20 conduit entry
ATEX, EEx d
E
Cast aluminum, Integral Mount with
3
⁄
4
" NPT conduit entry
ATEX, EEx ia
F
Cast aluminum, Integral Mount with M20 conduit entry
ATEX, EEx ia
G
316 SS, Integral Mount with
3
⁄
4
" NPT conduit entry
ATEX, EEx ia
H
316 SS, Integral Mount with M20 conduit entry
ATEX, EEx ia
HOUSING MATERIAL, MOUNTING AND CONDUIT ENTRY
2
The bottom 3 inches of SIL 2
direct insertion probes are
inactive. The inactive area is
used to detect float failure.
Consult factory for process
temperatures of 500°–850° F
(260°–455° C)
Direct insertion model only.
Consult factory for process
temperatures above +200° F
(+95° C)