![Magnetic MPB-311 Скачать руководство пользователя страница 79](http://html2.mh-extra.com/html/magnetic/mpb-311/mpb-311_operating-instructions-manual_4792658079.webp)
79
MPB-311
Mounting the optional mounting pillar for access-control devices
Additional steps for the subsequent ordering of the mounting pillar
If the mounting pillar was ordered subsequently, you must carry out the following
steps before mounting the mounting pillar:
1. Drill two holes with a diameter of 10 mm for the mounting pillars in the cage
half.
2. Either place a M8 blind rivet nut or cut a M8 thread in the 10 mm holes.
3. Drill a hole with a diameter of 30 mm for the pull wires and lines.
600
10
1
Ø 10
Ø 30
45°
Mag00898a
Ø 10
1052
3
1
1
2
Fig. 51:
Required holes for mounting pillar (all dimensions in mm)
1 Borehole diameter 10 mm either with M8 blind rivet nut or M8 thread for fastening
U-profile (2x)
2 Borehole diameter 30 mm for pull wires and lines (1x)
3
Standard height for implementation by Magnetic
4. Pull the pull wires or lines for the mounting pillar through the outer supports of
the cage half.