39
MPB-311
Mounting
7.5.4
Foundation and empty conduit plans
Example
1
2
4
3
min 800
150
Mag01127a
Fig. 12:
Example of foundation structure with empty conduits, floor covering and base
frame (dimensions in mm)
1 Finished paving such as interlocking stones or cobblestones, flush with the attachment
plates
2 Gravel and sand layer
3
Foundation C35/45 XD3 XF2 with reinforcement, foundation depth: at least 800 mm,
frost-proof
4
Base frame level and horizontal, fill any hollows under the base frame
Key for foundation and empty conduit plans
Marking
Description
F
Foundation anchor, holes for anchor rods
Hilti HIT-Z-R M10 x 160 A4: Drilling diameter 12 mm, drilling depth 105 mm
Observe separate instructions for foundation anchors.
F2
Foundation anchor, holes for anchor rods
Hilti HIT-Z-R M10 x 160 A4: Drilling diameter 12 mm, drilling depth 95 mm
Observe separate instructions for foundation anchors.
LR
Possible position for empty conduits. Lay empty conduits separately for mains
cable and control lines. Allow empty conduits to protrude approx. 50 mm above
foundation and lines to protrude at least 5 m from the empty conduits.
N
Levelling screws to align the base frame
Table 8:
Key for foundation and empty conduit plans