IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 61
4.3.3.7
Initialize Parameters (A01-05)
Use this parameter to reset the VFD to its factory default settings or transfer parameters.
Table 4-9: Initialize Settings
4.3.3.8
Password Entry (A01-06)
This parameter enables the user to set a password that inhibits the programming of the parameters. This function
is used in conjunction with the access level parameter A01-01. To set the password, enter a password number in
parameter A01-07 and press the
key. If A01-06 is not the same as A01-07, A01-01 cannot be changed once
A01-01 is set to 0 or 1. When A01-06 is the same as A01-07, A01-01 can be changed.
To create a password, when A01-06 is displayed, press the
and
key simultaneously to reveal A01-07.
Setting
Description
0
No Initialization
(factory default)
1110
User Default
(defaults)
Resets parameters to the values saved by the user as User Settings. User Settings are stored
when parameter O02-03 is set to “1: Set defaults”.
NOTE:
User Initialization resets all parameters to a user-defined set of default values previously
saved to the VFD. Set parameter O02-03 to 2 to clear the user-defined default values.
5432
Cntrl Int
→
Term
Moves the parameters stored in the control board and copies them to the interface board (S4IF).
5550
Control Init (OPE04 Reset)
An oPE04 error appears on the keypad when a interface card with settings saved to its built-in
memory is installed in a VFD that has edited parameters. Set A01-05 to 5550 to use the
parameter settings saved to the interface board (S4IF) memory.
7770
Swap Setup
Prepares all modified and user parameters for terminal board (S4IF) replacement. This will also
clear a parameter set stored in the keypad.
8880
Swap Exe
Finalizes interface board (S4IF) swap process once A01-05 = 7770 has been executed and the
new interface board (S4IF) has been installed.
Содержание Impulse G+ series 4
Страница 20: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 20 Figure 2 1 Capacitor Reform Diagrams...
Страница 30: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 30 Figure 3 1 Typical Connection Diagram...
Страница 53: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 53 4 3 2 Menu Structure Figure 4 1 Menu Structure...
Страница 243: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 243 Figure B 5 Figure B 6 Figure B 7...
Страница 246: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 246 Figure B 8 Figure B 9 Figure B 10 Figure B 11...
Страница 248: ...IMPULSE G VG Series 4 Adjustable Frequency Vector Crane Controls Technical Manual November 2022...