3.2.1 Terminal Description
* SC when 24 VDC interface board is used.
Type
Terminal
Name
Function (Signal Level)
Main Circuit
R/L1,
S/L2,
T/L3
AC power supply input
AC power supply input
U/T1,
V/T2,
W/T3
VFD output
VFD output (connected to motor)
B1, B2
Braking resistor connection
Braking resistor connection
+2, +1
DC reactor connection
When connecting a DC reactor, remove the short-circuit bar b2 and +1.
+1, (–)
DC power supply input
DC power supply input (+1: positive; (–): negative)
Ground
Ground to local grounding codes
C
on
tro
l C
irc
ui
t
Digital Inp
uts
S1
Digital input 1
Inputs are programmable
H01.01 ~
H01.07
Interface Board Options:
120 VAC,
42-48 VAC,
24 VAC,
24 VDC
±10%
S2
Digital input 2
S3
Digital input 3
S4
Digital input 4
S5
Digital input 5
S6
Digital input 6
S7
Digital input 7 (if present)
X2*
Digital input common
Common for control signal
Analog Inputs
+V
Power supply output
Analog input power supply
+10.5 VDC (20 mA max)
A1
Analog input 1
Inputs are programmable
H03.01
0 to 20 mA (250
Ω
) – A1 only
4 to 20 mA (250
Ω
) – A1 only
0 to +10 VDC (20 k
Ω
)
A2
Analog input 2
H03.09
AC
Analog common
0V
Safe Disa
ble
In
put
HC
Safe disable power supply
+24 VDC (max 10 mA)
NOTE:
Disconnect wire jumper between HC
and H1/H2 when using the safe disable input.
H1
Safe disable input 1
Open: Output disabled
Closed: Normal Operation
H2
Safe disable input 2 (if present)
Pulse T
rain
RP
Pulse Input
Pulse Input frequency reference
H06.01
0 to 32kHz (3 k
Ω
impedance) ±5%
High level voltages 3.5 to 13.2
Low level voltages 0.0 to 0.8
Duty Cycle (on/off) 30% to 70%
MP
Pulse Output
Pulse output frequency
H06.06
0 to 32kHz ±5% (load: 1.5 k
Ω
)
Digital Outputs
MA
N.O. contact output
Factory setting: brake output
H02.01
Dry contact capability:
250VAC 1A or less,
30VDC 1A or less
MB
N.C. contact output
MC
Contact output common
P1
Photo coupler output 1
Outputs are programmable
H02.02 ~
H02.03
Photo-coupler 48VDC,
50mA or less
P2
Photo coupler output 2
PC
Photo coupler output common
0V
A
n
alog
Output
AM
Analog output 1
Output is programmable
H04.01
0 to +10 VDC, 2mA or less, 8-bit
resolution
AC
Analog common
0V
Communication
Mo
dbus
R+
Communications input (+)
Modbus communication
RS-485 or RS-422.
H05.01 ~
H05.08
RS-485/422
Modbus, 115.2 kbps max.
R-
Communications input (-)
S+
Communications output (+)
S-
Communications output (-)
I(G)
Signal Common
0V (shield)
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...