Flex M Engineered Receiver Instruction Manual
May 2019
Page 19 of 50
Figure 8. GEN2 RF/CPU Module Wiring
4.2.1 RF/CPU LED OPERATION
When the Flex M system supplies power to the RF/CPU module, there is a series of LEDs that indicate
the RF/CPU module’s status.
Figure 9. GEN2 RF/CPU Module LED Placement
•
WDG/ONLINE LED:
o
1 Green Blink indicates normal operating WDG
o
2 Amber Blinks indicates RF communication loss with transmitter or when the transmitter
is powered off
o
3 Amber Blinks indicates a read/write error to an attached Flex M module
o
6 Amber Blinks indicates that the machine stop has been pressed or that there is an
internal machine stop error
•
RF MSG LED:
o
Green Blinks indicates radio frequency messages received. This confirms
communication between transmitter and receiver.
•
RF SIGNAL LEDs:
o
Indicates the strength of the RF communication signal from the transmitter. A weak signal
is indicated by only the red LEDs illuminated. As the signal strength increases, amber
and then green LEDs will light. Green LEDs indicate a strong signal.
•
E-STOP LED
o
Bicolor LED. Yellow indicator when K1 Relay is active. Green indicator when K2 Relay is
active