Parameter Table
Table 4: Related Parameters
Parameter
Code
Display
Function
Range
Initial
Value
F2-01
AI Function Sel
0, 1
0
0
3ch Individual
Option card input terminals V1,
V2, and V3 replace drive input
terminals A1, A2, and A3.
1
3ch Addition
Input signals to terminals V1, V2,
and V3 are added together to
create the frequency reference.
F2-02
AI Input Gain
Sets the gain for the input signal to
the analog card.
-999.9–999.9%
100.0
F2-03
AI Input Bias
Sets the bias for the input signal to
the analog card.
-999.9–999.9%
0.0
H3-02
Term A1 FuncSel
Sets the function of terminal A1.
0–31
0
H3-03
Terminal A1 Gain
Sets the level of the input value
selected in H3-02 when 10 V is
input at terminal A1.
-999.9–999.9%
100.0
H3-04
Terminal A1 Bias
Sets the level of the input value
selected in H3-02 when 0 V is
input at terminal A1.
-999.9–999.9%
0.0
H3-06
Terminal A3 Sel
Sets the function of terminal A3.
0–31
1F
H3-07
Terminal A3 Gain
Sets the level of the input value
selected in H3-06 when 10 V is
input at terminal A3.
-999.9–999.9%
100.0
H3-08
Terminal A3 Bias
Sets the level of the input value
selected in H3-06 when 0 V is
input at terminal A3.
-999.9–999.9%
0.0
H3-10
Terminal A2 Sel
Sets the function of terminal A2.
0–31
0
H3-11
Terminal A2 Gain
Sets the level of the input value
selected in H3-10 when 10 V (20
mA) is input at terminal A2.
-999.9–999.9%
100.0
H3-12
Terminal A2 Bias
Sets the level of the input value
selected in H3-10 when 0 V (0 or 4
mA) is input at terminal A2.
-999.9–999.9%
0.0
H3-13
Filter Avg Time
Sets a primary delay filter time
constant for terminals A1, A2, and
A3. Used for noise filtering.
0.00–2.00 sec
0.03
Parameter
Code
Display
Function
Analog Output
Level
Unit
U1-21
AI Opt Ch1 Level
Displays the input voltage to
terminal V1 on analog input card
AI-A3.
10 V: 100%
0.1%
U1-22
AI Opt Ch2 Level
Displays the input voltage to
terminal V2 on analog input card
AI-A3.
10 V: 100%
0.1%
U1-23
AI Opt Ch3 Level
Displays the input voltage to
terminal V3 on analog input card
AI-A3.
10 V: 100%
0.1%