background image

8/12

LH70 initial Setup Manual

FLICKER

(flicker control)

SLEEP

(sleep)

Step 5

Inhibition Weak

Inhibition Strong

off

Flickering of the smallest digits can be suppressed in two stages

default

1 min.

none

10 min.

1h

5 min.

30 min.

If no operation or scale movement is performed for a certain 
period of time, the display will turn off.

default

6

When the Detailed Settings are complete, switch to the normal display.

Press

key. 

This completes the initial settings.

.

D

e

ta

ile

S

et

tin

gs

Содержание LH70

Страница 1: ...of use Contents Page Preparations before making the initial settings checking conditions of use 2 to 3 How to set up Basic Settings 4 to 6 How to set up Detailed Settings continued from Basic Setting...

Страница 2: ...ent unit to be used for each axis The resolutions that can be selected are length and angle Expanded selections increase the number of options Length 0 05 to 100 m See Tables 1 2 and 3 or Angle 1 seco...

Страница 3: ...linear compensation 600 m m Expanded selections 1000 m m Flicker control Flickering of the smallest displayed digit can be suppressed Set the level of flicker suppression OFF Function stop 1 Weak 2 St...

Страница 4: ...g display appears Note If you change the basic settings Detailed Settings will be reset to the factory defaults Configure the basic settings Choose one of the following methods of operation Standby ke...

Страница 5: ...athe function is selected STANDARD General area U S A JAPAN default Basic Settings 1 Use key to change the basic setting item 2 The setting selection can be switched with key on the right side of the...

Страница 6: ...leted the basic settings exit this mode and move to Detailed Setting mode How to set up Basic Settings 3 3 Key to be used at the end of the basic setting mode LH70 How to Exit Basic Setting Mode Press...

Страница 7: ...input resolution cannot be selected Polarity changes with key To display the diameter double display turn on on the display axis Angle display Length display Extended resolution Press the edit key No...

Страница 8: ...allest digits can be suppressed in two stages default 1 min none 10 min 1h 5 min 30 min If no operation or scale movement is performed for a certain period of time the display will turn off default 6...

Страница 9: ...in advance for necessary items Also do not perform any operation other than the explanation Factory Default All Clear Mainly used keys Reference key Setup key How to check the software version Power...

Страница 10: ...key P key Canned cycle key Numeric key Datum point value setting key Status lamp Function key Appendix 1 Front panel Display Status Display Status Measurement unit not connected Storage data error Spe...

Страница 11: ...crews Use screws to secure it in place Use screws to secure it in place SZ70 1 Use screws to secure it in place Scale Head Resolution Adapter Counter SR128 GB A 0 5 m SZ70 1 LG20 LH70 71 71A 72 LY71 7...

Страница 12: ...screws to secure it in place SZ70 1 Counter unit Screws DK series CE29 Use screws to secure it in place Gauge Resolution Adapter 1 Adapter 2 Counter DG B 0 5 m DZ51 SZ70 1 LG20 LH70 71 71A 72 LY71 72...

Отзывы: