3/12
LG20 initial Setup Manual
Items
Indication
Description
Settings
Display resolution
and polarity
Sets the resolution to be displayed for each
axis. A value lower than the input resolution
cannot be set. Selects the value for each axis,
including the polarity (+/-).
The default value is set by the basic settings.
Length: 0.1 to 100μm
Display switching
Each display axis can be selected for the
length measurement unit input axis.
Input axis:
IN-1: 1st input axis
IN-2: 2nd input axis
IN-3: 3rd input axis
IN - -: No display
Axis label
Upper
:
X
Middle
:
Y
Display axis label selection
Upper axis: "X" or "Z"
Middle axis: "Y" or "Z"
Compensation
value
Settings of linear compensation and
segmented error compensation
Err OFF
:
off
Lin Err
:
linear compensation
±
600μm/m
Flicker control
Flickering of the smallest displayed digit can be
suppressed. Set the level of flicker suppression.
OFF: Function stop
1: Weak
2: Strong
Sleep
The display turns off when there is no
movement of the length measurement unit or
key operation for a certain period of time while
the power is on.
It will return when the length measurement unit
is moved or the Key operation is performed
again.
OFF: Do not put to sleep
1: 1 minute later
5: 5 minutes later
10:10 minutes later
30:30 minutes later
60: 60 minutes later
Preparations before making the initial settings (2/2)
Check the usage conditions for Detailed Settings.
(Since the settings conditions can be changed later, use the default values to skip items for which
the conditions have not been confirmed)
default
Upper axis
Middle axis
Lower axis
Detailed Settings Items
NOTE:
Can be used with LG20-1 and LG20-2.