background image

10/12

LG20 initial Setup Manual

No.

Name

No.

Name

Axis label

Standby key

Φ lamp

Axis select key

Counter display

Numeric key

RESET key

Function key

P key

SETUP key

Appendix 1

Front panel

Display

Status

Display

Status

Measurement unit not 
connected

Storage data error

Speed over (NOTE

Overflow

Power failure

Alarm indication

NOTE: When using an adapter connection (SZ**), no speed override indication is shown, but rather an error message.

Blinking)

LG20

Содержание LG20

Страница 1: ...heck the conditions of use Contents Page Preparations before making the initial settings checking conditions of use 2 to 3 How to set up Basic Settings 4 to 6 How to set up Detailed Settings continued...

Страница 2: ...1711 SR 1711R 0 5 m HK C HK CR SZ05 T01 SR801 MSS 101 SR801R 0 5 m HK 1 C HK 2 C SZ05 T01 SR801 MSS 101 SR801R 0 5 m CE07 C SZ51 MS01 SZ70 1 SR10 SR30 SR50 SR50 R 0 5 m HK 4 C HK6 CR SZ05 T01 SR118 0...

Страница 3: ...Lin Err linear compensation 600 m m Flicker control Flickering of the smallest displayed digit can be suppressed Set the level of flicker suppression OFF Function stop 1 Weak 2 Strong Sleep The displa...

Страница 4: ...pter is energized Turn on key the LED light changes from blinking to off and then press and hold key for 3 seconds Standby key light Item feed Key SET UP key Enter key Axis selection Key Continued on...

Страница 5: ...gs selection can be switched with key on the right side of the counter display 3 To define the new value press key COUNTRY Destination SIG RES Measuring unit resolution STANDARD General area U S A JAP...

Страница 6: ...s key or key The display changes to Pressing key displays Press key The display will be Press key The display returns to normal This completes the basic settings Step 3 Once you have completed the bas...

Страница 7: ...c settings and want to reconfigure only the advanced settings you can do the same Basic Settings Press the setup key in the normal count display state Selection of each display axis and measurement un...

Страница 8: ...est digits can be suppressed in two stages default 1 min none 10 min 1h 5 min 30 min If no operation or scale movement is performed for a certain period of time the display will turn off 6 When the De...

Страница 9: ...cessary items Also do not perform any operation other than the explanation Factory Default All Clear Mainly used keys Blindfold key Setup key 1 Hold down the Blindfold key and key at the same time to...

Страница 10: ...RESET key Function key P key SETUP key Appendix 1 Front panel Display Status Display Status Measurement unit not connected Storage data error Speed over NOTE Overflow Power failure Alarm indication N...

Страница 11: ...crews Use screws to secure it in place Use screws to secure it in place SZ70 1 Use screws to secure it in place Scale Head Resolution Adapter Counter SR128 GB A 0 5 m SZ70 1 LG20 LH70 71 71A 72 LY71 7...

Страница 12: ...screws to secure it in place SZ70 1 Counter unit Screws DK series CE29 Use screws to secure it in place Gauge Resolution Adapter 1 Adapter 2 Counter DG B 0 5 m DZ51 SZ70 1 LG20 LH70 71 71A 72 LY71 72...

Отзывы: