CARE  AND  MAINTENANCE

CARE AND MAINTENANCE

     1)  Be sure to unplug the unit before cleaning or servicing.

     2)  Do not use gasoline, thinner or other chemicals to clean 

          the unit.

     3)  Do not wash the unit directly under a tap or using a  hose.

          It may cause electrical danger.

     4)  If the power cord is damaged, it should be repaired by 

        

  

customer service or the manufacturer.

IMPORTANT:

1.   Air filter

-     Clean the air filter at least once every two weeks to prevent 

   degrading fan operation because of dust. 
-     Removal 

      This unit has two filters.  Grasp the upper filter tab(Fig.25), 

,,

,,

      pull the filter  out  then  up . Remove the lower filter by 

      loosening the screw, taking down the air inlet grille, then

      removing the air filter as shown in Fig.26 & 27.    
-     Cleaning 

      Wash the air filter by immersing it gently in warm water

     with a neutral detergent. Rinse the filter   and dry in a

 shady place. 

-     Mounting 

Reinsert the upper air filter from the top after cleaning, attach

      the lower air filter on the air inlet grille, then install the grille

      by using the screw.

2.   Unit enclosure

-     Use a lint-free cloth soaked in neutral detergent to clean  

      the unit enclosure. Finish with a dry clean cloth.

3.   Unit idle for a long time

,,

,,

-     Remove the rubber plug at the back of the unit and attach

      a hose to drain outlet

. Place the open end of the hose 

      directly over a drain or separate container to dispose of 

  

    

later (See Fig.22 & 23).

-     Remove  the plug from the bottom drain outlet, all the water 

       in the bottom tray should drain out (See Fig.24). 
-     Keep the appliance running on FAN mode for half a day in 

      a warm room to dry the appliance inside and prevent mold

      forming.
-     Stop the appliance and unplug it, wrapped the cord and 

      bundle it with the tape(Fig.28). Remove the batteries from

      the remote controller.
-     Clean  the air filter and reinstall it.
-     Unscrew the exhaust hose to the right or left and pull out

to detach(Fig.29), keep it safety, and cover the window

(wall) hole with the adaptor cap.

Fig.29

14

Fig.25

Air filter
(slide out)
 

Fig.26

Fig.28

Remove three
screws and 
take the air
intake grille 
down 

Remove the air filter 
out from the grille

Fig.27

Band

Power 
cord

Содержание P-14PE

Страница 1: ...Before operating this product please read the instructions carefully and save this manual for future use MODEL P 14PE For any service needs call 1 855 368 8606 OWNER S MANUAL...

Страница 2: ...by a responsible adult or considered capable enough to operate the appliance safely Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it m...

Страница 3: ...ontrol panel operating instructions 5 Operating instructions 6 Placement 8 Window kit installation 8 Exhaust hose installation 12 Water drainage 13 Care and maintenance 14 Troubleshooting tips 15 AIR...

Страница 4: ...operly or if it has been dropped or damaged Never use the power plug to turn unit on or off Do not cover or obstruct the inlet or outlet grilles Do not use hazardous chemicals to clean or come into co...

Страница 5: ...rs and liquids in the vicinity of this or any other appliance Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any prong from the power cord WARNING El...

Страница 6: ...4 5 Model A Model B Control Panel Horizontal Louver Blade operate manually Remote signal receptor Caster wheels Carrying Handles on each side 1 2 3 4 5 Fig 1 Rear 6 7 8 9 10 11 Upper Air Filter Behin...

Страница 7: ...the same time for 3 seconds 3 Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjuction with the buttons TIMER button 4 Used to initiate the SLEEP mode SLEEP button 6 2 Powe...

Страница 8: ...e temperature you have selected and thecurrent room temperature While the unit is on press the Timer button the TIMER OFF indicator light illuminates This indi cates the Auto Stop program is initiated...

Страница 9: ...the louver s doing o will cause damage to the unit Ensure the louver is fully opened during heating operation Adjust the air flow direction automatically Fig 6 When the unit is turned ON the louver o...

Страница 10: ...for easy mobility but it should only be rolled on smooth flat surfaces Use caution when rolling on carpet surfaces Do not attempt to roll the unit over objects The unit must be placed within reach of...

Страница 11: ...window is less than 26 5 inches Open the window sash and place the window slider kit on the window sill See Fig 11 3 Cut the foam seal adhesive type to the proper length and attach it on the top of t...

Страница 12: ...f the width of window is less than 26 5 inches Open the window sash and place the window slider kit on the window sill See Fig 15 3 Cut the foam seal adhesive type to the proper length and attach it o...

Страница 13: ...d the window sill when there is the gap between them as shown below Window kit Window sill Fig A Gap Window kit Window sill Fig A1 White foam seal Seal the white foam seal Window kit Gap Window frame...

Страница 14: ...e previous pages for window kit installation 2 Place the Exhaust hose over against the air outlet opening hook See Fig 19 and flat the other end See Fig 20 for quick installation IMPORTANT DO NOT OVER...

Страница 15: ...r level of the bottom tray reaches a predetermined level Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Fig 24 Restart the machine and wait for t...

Страница 16: ...er on the air inlet grille then install the grille by using the screw 2 Unit enclosure Use a lint free cloth soaked in neutral detergent to clean the unit enclosure Finish with a dry clean cloth 3 Uni...

Страница 17: ...dust 2 Not cool enough Place the unit on a flat level ground if possible This is normal The ground is not level or not flat enough The sound comes from the flowing of the refrigerant inside the air c...

Страница 18: ...MAGNAVOX and SMART VERY SMART are registered trademarks of Koninklijke Philips N V and are used under license from Koninklijke Philips N V...

Отзывы: