background image

INSTALLATION  INSTRUCTIONS 

Exhaust hose installation:

 The exhaust hose and adaptor must be attached or removed

 in accordance with the usage mode. 

The duct can be compressed or extended moderately 

according to the installation requirement, but it is 

desirable to keep the duct length to a minimum.  

 1.  Install the window Exhaust adaptor B  onto the exhaust 

    

      hose as shown in Fig.18. Refer to the previous 

    

      pages for window kit installation.

  

  

 2.  Place the Exhaust hose over against the air outlet opening

    

      hook(See Fig.19) and flat the other end(See Fig.20) for 

    

     quick installation.

  

IMPORTANT:

  

   DO NOT OVER BEND THE DUCT (SEE Fig.21)

Fig.18

Fig.21

    

    

    

    

 

    

    

    

    

  

   

Note: 

  

   

Cover the hole using the adaptor cap when not in use. 

     COOL,HEAT(heat pump type) 

or  AUTO  

    

 mode

   FAN, DEHUMIDIFY or

 HEAT(electrical heat type)

  

   

mode 

  

   Attach

  

 Remove

CAUTION:

  

   Make sure that there is no obstacle around the air outlet of

  

   the exhaust hose (in the range of 1.6 ft.) in order to the 

  

   exhaust system works properly.

12

Fig.20

Push in

Hook

Fig.19

Содержание P-14PE

Страница 1: ...Before operating this product please read the instructions carefully and save this manual for future use MODEL P 14PE For any service needs call 1 855 368 8606 OWNER S MANUAL...

Страница 2: ...by a responsible adult or considered capable enough to operate the appliance safely Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it m...

Страница 3: ...ontrol panel operating instructions 5 Operating instructions 6 Placement 8 Window kit installation 8 Exhaust hose installation 12 Water drainage 13 Care and maintenance 14 Troubleshooting tips 15 AIR...

Страница 4: ...operly or if it has been dropped or damaged Never use the power plug to turn unit on or off Do not cover or obstruct the inlet or outlet grilles Do not use hazardous chemicals to clean or come into co...

Страница 5: ...rs and liquids in the vicinity of this or any other appliance Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any prong from the power cord WARNING El...

Страница 6: ...4 5 Model A Model B Control Panel Horizontal Louver Blade operate manually Remote signal receptor Caster wheels Carrying Handles on each side 1 2 3 4 5 Fig 1 Rear 6 7 8 9 10 11 Upper Air Filter Behin...

Страница 7: ...the same time for 3 seconds 3 Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjuction with the buttons TIMER button 4 Used to initiate the SLEEP mode SLEEP button 6 2 Powe...

Страница 8: ...e temperature you have selected and thecurrent room temperature While the unit is on press the Timer button the TIMER OFF indicator light illuminates This indi cates the Auto Stop program is initiated...

Страница 9: ...the louver s doing o will cause damage to the unit Ensure the louver is fully opened during heating operation Adjust the air flow direction automatically Fig 6 When the unit is turned ON the louver o...

Страница 10: ...for easy mobility but it should only be rolled on smooth flat surfaces Use caution when rolling on carpet surfaces Do not attempt to roll the unit over objects The unit must be placed within reach of...

Страница 11: ...window is less than 26 5 inches Open the window sash and place the window slider kit on the window sill See Fig 11 3 Cut the foam seal adhesive type to the proper length and attach it on the top of t...

Страница 12: ...f the width of window is less than 26 5 inches Open the window sash and place the window slider kit on the window sill See Fig 15 3 Cut the foam seal adhesive type to the proper length and attach it o...

Страница 13: ...d the window sill when there is the gap between them as shown below Window kit Window sill Fig A Gap Window kit Window sill Fig A1 White foam seal Seal the white foam seal Window kit Gap Window frame...

Страница 14: ...e previous pages for window kit installation 2 Place the Exhaust hose over against the air outlet opening hook See Fig 19 and flat the other end See Fig 20 for quick installation IMPORTANT DO NOT OVER...

Страница 15: ...r level of the bottom tray reaches a predetermined level Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Fig 24 Restart the machine and wait for t...

Страница 16: ...er on the air inlet grille then install the grille by using the screw 2 Unit enclosure Use a lint free cloth soaked in neutral detergent to clean the unit enclosure Finish with a dry clean cloth 3 Uni...

Страница 17: ...dust 2 Not cool enough Place the unit on a flat level ground if possible This is normal The ground is not level or not flat enough The sound comes from the flowing of the refrigerant inside the air c...

Страница 18: ...MAGNAVOX and SMART VERY SMART are registered trademarks of Koninklijke Philips N V and are used under license from Koninklijke Philips N V...