LED Status Indicator Operation:

LED is off = Alarm is disarmed.

LED is flashing = Alarm is armed.

LED is flashing fast = Automatic arming timer or RF protection mode timer is counting down.

LED is on steady = Alarm is in the valet mode. (Ignition key is “on”)

LED flashes once every 5 seconds = Alarm is in the valet mode. (Ignition key is “off”)

LED is flashing in a 2 flash-pause sequence = Tamper warning, security system has been trigger from the 

hood/trunk switch or electronic sensor.

LED is flashing in a 3 flash-pause sequence = Tamper warning, security system has been triggered from

an opened door.

Parking Light Flash Alarm Status Indication:

One light flash = Alarm is armed.
Two light flash = Alarm is disarmed.
Three light flash = Tamper w alarm is disarmed.

Horn/Siren Chirp Alarm Status Indication:

Note: This feature can be programmed off, see “Remote Feature Programming” for details.
One chirp = Alarm is armed and all input trigger wires are clear.
Two chirps = Alarm is disarmed and has not been tampered with.
Four chirps = Tamper w security system is disarmed.

Power Door Lock/Unlock:

(If Installed)

1. Arm the alarm with the transmitter, the locks will become locked.

2. Disarm the alarm with the transmitter, the locks will become unlocked.

RF Tamper Re-Arm:

Note: This feature is activated automatically when the alarm is programmed for automatic arming. See

“Remote Feature Programming” for details. (Page 14-15)

1. Alarm must be programmed for automatic arming. 

2. Close all protected entrances and arm the alarm with the remote transmitter. The LED will be flashing

at a normal rate.

3. Wait 5 seconds and disarm the alarm using the remote transmitter. The LED will begin to flash fast.

(Automatic arming indicator)

4. Wait 60 seconds and the alarm will become rearmed.

5. Repeat steps 1 through 4. When the LED starts flashing fast, open one of the protected entrances

(door) the LED will be off and remain off.

60 Second Re-Arm Timer and Re-Lock Function:

If your security system has become triggered, the horn/siren will sound for 60 seconds and then stop

and re-set to a fully armed condition.
Note: If a protected entrance is left open, your security system will remain triggered for two more 60

second cycles then fully re-arm excluding the door input trigger. (Door input trigger is no longer

functional) Closing the entrance will re-set the door input trigger within 7 seconds. 

Step 11: Speciality Feature and Optional Equipment Testing

Содержание PL50

Страница 1: ...t 1997 Magnadyne Corporation For Technical Assistance 800 638 3600 For Fax on Demand Technical Assistance 800 994 9977 Must be a Registered Dealer to Use Fax on Demand System INSTALLATION MANUAL Remot...

Страница 2: ...ith the alarm kit is one pin switch and one mounting bracket To install the switch either in the truck or under the hood find a suitable location where the switch will make contact with the hood or tr...

Страница 3: ...equiring positive voltage or more than 300mA to trigger the horn relay will require an additional relay to increase current capabilities Blue Wire with White Stripe Channel 3 Output Applies to PL60 On...

Страница 4: ...hting dimmer switch Damage to the dimmer will result use a volt meter to test the connection point before connecting the red white wire While checking rotate the dimmer switch to make sure you do not...

Страница 5: ...Wire Main Ground Input Connect the black wire directly to the frame of the vehicle Use a bolt and nut to secure the wire Scrape away any grease or paint that might prevent a good connection Yellow Wi...

Страница 6: ...Brown Wire Unlock Green Wire Lock Blue Wire Unlock Violet Wire 3 Pin Black Plug ALA DL1 Relay Pack Power Door Lock Unlock Activation 3 Wire Positive Trigger Door Lock System Lock Out 12 Volts Input U...

Страница 7: ...ne wire to lock and unlock the doors Example When the door lock controller sees a signal thru a resistor it will unlock If a signal is received without a resistor the doors will lock Some use 2 resist...

Страница 8: ...r Ground To 12V or Ground Driver s Door Rear Door Passenger Door Switch Door Lock Relay Control Module Lock Unlock 12V Must Add ALA984H Relay Drivers Door Switch Cut Unlock Remaining Doors Unlock Driv...

Страница 9: ...ection of this manual Page 17 ACC START OFF ON Cut Starter 2 Pin Plug from Control Module Unlock Driver s Door First Wiring for 5 Wire Ground at Rest Door Locking Systems 87 87A 85 86 30 87 87A 85 86...

Страница 10: ...th White Stripe Output from Alarm Flashing Lights White Orange Wire Optional Dome Light Illumination and Lighted Pathway Illumination Output to Domelight or Input to Relay or White Purple Wire Orange...

Страница 11: ...Using Optional 30 Amp Relay Applies to PL50 Only 87 86 85 30 Orange Wire SPST ALA984H Relay Not Supplied Output to Dome Light or To Constant 12 Volts Input to Relay or Insert Orange Wire into the Fir...

Страница 12: ...e Valet Override Switch is in the Off Position S t e p 1 Switch in Off Position Switch in On Position Valet Override Switch Switch the Valet Switch On then Off 1 Time The horn siren will stop sounding...

Страница 13: ...2 Regular Arm Dis 2 S t e p 6 To Code 2 Button Push the Valet Switch 2 Times Represent 1 Time On Off The LED will be solid red and the horn siren will chirp 1 time S t e p 7 2x Push the 2 Button The...

Страница 14: ...rming Automatic Arming of Alarm Off 3 Silent Arming from 3 Button Transmitter s Aux Button Off 4 Safety Illumination Sentinel System Off R Disarm the Security System The LED will be off and the horn s...

Страница 15: ...seconds after door is closed and rearm 60 seconds after remote disarm 4 Beeps Automatic Arming On Alarm will arm 70 seconds after door is closed and rearm 60 seconds after remote disarm 5 Beeps Automa...

Страница 16: ...nner regardless of the alarm model Test each feature by following the procedures enclosed to insure proper operation Remote Panic 1 Press and hold the arm disarm for regular transmitters or panic butt...

Страница 17: ...e security system is in the valet mode Note If the unit is in valet mode the LED will be on solid when the ignition key is on only When the ignition key is off the LED will flash once every 5 seconds...

Страница 18: ...with the transmitter the locks will become locked 2 Disarm the alarm with the transmitter the locks will become unlocked RF Tamper Re Arm Note This feature is activated automatically when the alarm i...

Страница 19: ...on deletable protective measure Channel 2 Output Press and hold the channel 2 activation button for 3 seconds The designated channel 2 output wire from the alarm become grounded for as long as button...

Страница 20: ...View of Housing Dip Switches Black Wire Antenna Do Not Ground Power Door Lock Harness Socket Black Valet Override Socket Blue 1 2 3 ON Black Wire Ground to Vehicle Frame Yellow Wire To Ignition Switc...

Отзывы: