18
LED Status Indicator Operation:
LED is off = Alarm is disarmed.
LED is flashing = Alarm is armed.
LED is flashing fast = Automatic arming timer or RF protection mode timer is counting down.
LED is on steady = Alarm is in the valet mode. (Ignition key is “on”)
LED flashes once every 5 seconds = Alarm is in the valet mode. (Ignition key is “off”)
LED is flashing in a 2 flash-pause sequence = Tamper warning, security system has been trigger from the
hood/trunk switch or electronic sensor.
LED is flashing in a 3 flash-pause sequence = Tamper warning, security system has been triggered from
an opened door.
Parking Light Flash Alarm Status Indication:
One light flash = Alarm is armed.
Two light flash = Alarm is disarmed.
Three light flash = Tamper w alarm is disarmed.
Horn/Siren Chirp Alarm Status Indication:
Note: This feature can be programmed off, see “Remote Feature Programming” for details.
One chirp = Alarm is armed and all input trigger wires are clear.
Two chirps = Alarm is disarmed and has not been tampered with.
Four chirps = Tamper w security system is disarmed.
Power Door Lock/Unlock:
(If Installed)
1. Arm the alarm with the transmitter, the locks will become locked.
2. Disarm the alarm with the transmitter, the locks will become unlocked.
RF Tamper Re-Arm:
Note: This feature is activated automatically when the alarm is programmed for automatic arming. See
“Remote Feature Programming” for details. (Page 14-15)
1. Alarm must be programmed for automatic arming.
2. Close all protected entrances and arm the alarm with the remote transmitter. The LED will be flashing
at a normal rate.
3. Wait 5 seconds and disarm the alarm using the remote transmitter. The LED will begin to flash fast.
(Automatic arming indicator)
4. Wait 60 seconds and the alarm will become rearmed.
5. Repeat steps 1 through 4. When the LED starts flashing fast, open one of the protected entrances
(door) the LED will be off and remain off.
60 Second Re-Arm Timer and Re-Lock Function:
If your security system has become triggered, the horn/siren will sound for 60 seconds and then stop
and re-set to a fully armed condition.
Note: If a protected entrance is left open, your security system will remain triggered for two more 60
second cycles then fully re-arm excluding the door input trigger. (Door input trigger is no longer
functional) Closing the entrance will re-set the door input trigger within 7 seconds.
Step 11: Speciality Feature and Optional Equipment Testing