19
Power Requirements . . . . . . . . . . . . . . . . . . . . . . . .
12.5 Volts Negative Ground
Trigger Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Grounded Pin Switch, Positive Pin Switch,
Electronic Sensor Ground, 0.6 Volt Current Drop
Current Requirements . . . . . . . . . . . . . . . . . . . . . . .
Less Than 15mA Armed or Disarmed
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Programmable Automatic Arming Timer
Programmable Re-Arming Timer
60 Second RF Tamper Re-Arming Timer
5 Second Zone By-Pass Re-Activation Timer
Grounded Output Wire Capacity (White Wire) . .
500mA
Siren Output Wire Capacity . . . . . . . . . . . . . . . . . .
2 amps
Channel 2 Pulsed Output. . . . . . . . . . . . . . . . . . . .
300mA
By-Pass Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Zones
Transmitter Frequency . . . . . . . . . . . . . . . . . . . . . .
302mHz
Digital Code Combinations . . . . . . . . . . . . . . . . . .
500,000 Available
Code Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Trinary
Transmitter Channels . . . . . . . . . . . . . . . . . . . . . . .
2 Channels
Receiver Channels . . . . . . . . . . . . . . . . . . . . . . . . .
No More Than 3
Ignition Controlled Door Locking:
(Door lock activation must be installed)
When programmed on in “Remote Feature Programming”, ignition controlled locking is active 3 seconds
after the ignition key is set the on position, the door locks will automatically become locked. When the
ignition key is turned to the off position, the door locks will unlock.
Note: If a protected entrance (Door) is open when the ignition key is set to the on position, the door locks
will not lock. This is a non-deletable protective measure.
Channel #2 Output:
(If Installed)
Press and hold the channel #2 activation button for 3 seconds. The designated channel 2 output wire
from the alarm will become grounded for as long as button #2 is pressed.
Channel #3 Output:
(If Installed)
Press and hold the channel #3 activation button for approximately 3 seconds. After 3 seconds the alarm
will emit a ground signal from the channel #3 wire to operate the device connected to the channel #3
output wire of the alarm for as long as channel #3 button is pressed.
Dual Zone Sensor Pre-Warning Indicator:
(If Installed)
1. Close all protected entrances and place the alarm in an armed condition.
2. Rap the vehicles body panels to activate the pre-warning zone of any dual zone type sensor.
3. When the pre-warning indicator is triggered, the horn/siren will beep 1 time.
Step 10: Speciality Feature and Optional Equipment Testing
Specifications