Table 11.5: MOST150 data logging
The SMSC SpyNIC MOST150 is used to provide the MOST150 traffic data.
The data logger is not an active part of the bus system because it is working in a spy mode. The
device is able to log messages immediately after wake up.
Before the logging data are saved on the internal memory, they are buffered in a ring buffer. In
the case of a data rate peak, which exceeds the storage rate of the internal memory, storage of
data is still possible.
If the MOST150 data rate is permanent higher than the maximum storage rate, the data logger
will stepwise deactivate channels: first the MEP and MDP channel, then the control channel and
at last the status messages.
To ensure logging of maximum continuous data blocks a hysteresis is implemented. Before log-
ging MEP and MDP messages again, the ring buffer data has to be fully stored on the hard disk.
Before starting the logging of the MEP and MDP messages again the system sends a “Lost
Message”. This message contains information about how many messages of which type were
rejected.
11.9
ECL
Currently the ECL (Electrical Control Line) is only supported in conjunction with MOST150. In
general, the ECL is a slow LIN bus. The following ECL messages will be recorded:
EWU (Electrical Wake-Up)
STWU (System Test Wake-Up)
STP (System Test Parameters)
STR (System Test Results)
Undefined Pulse
Packet
MDP (MOST Data Packet),
MEP (MOST Ethernet Packet)
Filter
Control Messages on/off, Packet on/off, MDP on/off, MEP on/off, Status on/off,
MDP Transmit and Receive Address, Packet Length,
MEP Receive Address, Message Length