4.4 Error Codes
It gives an error message when the mains voltage is wrong or thermal. If you do not want the welding performance to be affected during installation,
the parameters such as wire diameter, torch, consumables used in the torch, wire type, wire diameter and gas type should be considered.
• The machine’s duty cycle rate may have been
exceeded
• Fan may not be operating
• Visually inspect the fan for proper operation.
Please contact the authorized service if it
does not operate
• The air inlet and outlet ducts may have been
blocked
• Open the air ducts
• The machine operating environment can be
extremely hot or lack of air
• Wait for a while to allow the machine to cool
down. If the failure disappears, try to run the
machine at lower amperage values
• Ensure that the machine is placed in an area
where it can work operate comfortably
E01
Thermal
Protection
• Temperature sensor may have failed or there
may be an electrical connection problem
E05
Temperature Sensor
Reading Failure
• Contact the authorized service
Error Code
Error
Reason
Solution