EN
www.magmaweld.com
RD 500 E
19
USER MANUAL | KULLANIM KILAVUZU
MAINTENANCE AND SERVICE
• Strictly follow the instructions contained in safety rules while servicing the machine.
• Before removing any screw on the machine for maintenance, power supply must be disconnected from the electric
lines and enough time should be allowed for capacitor discharging.
• Do not remove the warning labels on the device. Replace the worn/torn labels with the new ones. Labels
can be obtained from the authorized service.
• Check your clamps and cambles. Pay attention to the connections and the durableness of the parts. Replace the
damaged/defective parts with the new ones. Do not ever make aditions to/repair the cables.
NOTE: The above mentioned periods are the maximum ones that should be applied if no problems are encountered in your device.
Depending on the work load and contamination of your work environment, you can repeat the above processes more frequently.
4.1. Maintenance
Every 3 Months
• Clean and tighten fasteners such as bolts and nuts.
• Check the lead of the electrode pliers and earth pliers.
• Open the side covers of the machine and clean with low pressure dry air. Do not apply compressed air to electronic
components at close range.
Every 6 Months
Maintenance And Service
Never weld with the covers of the welder open.